Publications

Detailed Information

Correlation between bone quality evaluated by CT and implant primary stability in the posterior maxilla : 상악 구치부에서 골질과 임플란트 초기 안정성 사이의 상관 관계에 관한 연구

DC Field Value Language
dc.contributor.advisor임영준-
dc.contributor.author김지현-
dc.date.accessioned2017-07-19T08:21:51Z-
dc.date.available2017-07-19T08:21:51Z-
dc.date.issued2015-02-
dc.identifier.other000000026727-
dc.identifier.urihttps://hdl.handle.net/10371/130887-
dc.description학위논문 (석사)-- 서울대학교 대학원 : 치의과학과, 2015. 2. 임영준.-
dc.description.abstractABSTRACT-


Correlation between bone quality evaluated by CT
and implant primary stability in the posterior maxilla


Ji-Hyun Kim, D.D.S.
Department of Prosthodontics, Graduate School, Seoul National University
(Directed by Associate Professor Young-Jun Lim, D.D.S., M.S.D., Ph.D.)

Objectives. The aim of the present study was to examine the bone density objectively in implant sites of posterior maxillae using computed tomography and to evaluate possible correlations between age, gender, geometry of implants (design, diameter), maximum insertion torque measurements, and resonance frequency analysis (RFA) values.
Methods. 30 patients who treated with 60 implants in posterior maxilla area were evaluated. Two different types of dental implants were used (30 SLActive○R Bone level implant and 30 CMI IS-II active○R). The bone densities in each implant site were determined using CT and cat-egorized according to Mischs classification. The maximum insertion torque data and reso-nance frequency analysis (RFA) measurements were recorded.
Results. 30 patients who treated with 60 implants in posterior maxilla area were evaluated. Two different types of dental implants were used (30 SLActive○R Bone level implant and 30 CMI IS-II active○R). The bone densities in each implant site were determined using CT and cat-egorized according to Mischs classification. The maximum insertion torque data and resonance frequency analysis (RFA) measurements were recorded.
Conclusions. The bone density evaluated by CT showed a significant correlation with the pri-mary stability parameters. These values can provide the implant surgeon with an objective as-sessment of bone quality, which could result in modification of surgical technique, especially in situation where poor bone quality is suspected
-
dc.description.tableofcontentsCONTENTS

Ⅰ. INTRODUCTION
Ⅱ. MATERIALS AND METHODS
Ⅲ. RESULTS
Ⅳ. DISCUSSION
Ⅴ. CONCLUSION
REFERENCES
KOREAN ABSTRACT
-
dc.formatapplication/pdf-
dc.format.extent7689151 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectbone density-
dc.subjectHounsfield Units-
dc.subjectinsertion torque-
dc.subjectresonance frequency analysis-
dc.subjectPosterior Maxilla.-
dc.subject.ddc617-
dc.titleCorrelation between bone quality evaluated by CT and implant primary stability in the posterior maxilla-
dc.title.alternative상악 구치부에서 골질과 임플란트 초기 안정성 사이의 상관 관계에 관한 연구-
dc.typeThesis-
dc.contributor.AlternativeAuthorJi-Hyun Kim-
dc.description.degreeMaster-
dc.citation.pages32-
dc.contributor.affiliation치의학대학원 치의과학과-
dc.date.awarded2015-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share