dc.description.abstractAbstract

The relationship between primary implant stability by impact response frequency and 3D bone parameters

Sung-Chul Bok, DDS
Department of Oral and Maxillofacial Radiology,
Graduate School, Seoul National University
(Directed by Prof. Won-Jin Lee, MSD, PhD)

Purpose: This study is designed to investigate the relationship between stability by impact response frequency (SPF) and 3D bone micro parameters.

Materials and methods: The developed stability measurement method using analog inductive sensor was utilized to acquire the movement of implant models. 23 dental implantation models using pig rib bone samples were used. The SPF results from implantation models were compared with 3D micro parameters from micro-CT images. The data were analyzed by the SPSS program for linear regression.

Results: Our analysis clearly revealed that a strong positive correlation between SPF values and bone microstructure parameters including BV/TV, BV, BS, IS, BSD, Tb.Th, and Tb.N. On the other hand, there was a negative correlation between SPF values and bone microstructure parameters including BD/BW and Tb.Sp.
Conclusion: This work reported the primary implant stability by impact response frequency and 3D bone parameters using pig rib bone.The results indicate that SPF strongly correlates with bone parameters. Based on the present results, further studies should be conducted to identify the correlation between SPF and histological parameters of bone in human samples including more specimens.
-
dc.description.tableofcontentsIntrodction 1
Materials and Methods 8
Results 11
Discussion 13
Conclusion 17
Reference 18
Tables 27
Figures 30
Abstract in Korean 34
-
dc.formatapplication/pdf-
dc.format.extent1084629 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectprimary implant stability-
dc.subject3D bone parameters-
dc.subject.ddc617-
dc.titleThe relationship between primary implant stability by impact response frequency and 3D bone parameters-
dc.title.alternativeImpact response frequency에 의한 일차적 임플란트안정성과 3D bone parameter 들과의 관계-
dc.typeThesis-
dc.description.degreeMaster-
dc.citation.pages31-
dc.contributor.affiliation치의학대학원 치의과학과-
dc.date.awarded2015-08-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share