Publications

Detailed Information

The effect of reciprocating motion on the cyclic fatigue resistance of ProFile and ProTaper : ProFile과 ProTaper의 cyclic 피로저항에 미치는 reciprocating 운동의 효과

DC Field Value Language
dc.contributor.advisor이우철-
dc.contributor.author김승필-
dc.date.accessioned2017-07-19T08:26:08Z-
dc.date.available2017-07-19T08:26:08Z-
dc.date.issued2013-02-
dc.identifier.other000000008917-
dc.identifier.urihttps://hdl.handle.net/10371/130970-
dc.description학위논문 (석사)-- 서울대학교 치의학대학원 : 치의학과, 2013. 2. 이우철.-
dc.description.abstract1. Objectives
Recently, it has been shown that the reciprocating movement (RM), extended the lifespan of an F2 ProTaper instrument in comparison with continuous clockwise rotation (CR), in curved canals. The purpose of this study was to investigate the effect of RM on cyclic flexural stress (fatigue) on NiTi instruments with different cross-sections when they were driven with RM.

2. Methods
F2 ProTaper (PT) and #25/.06 taper ProFile (PF) instruments were used. Cyclic flexural fatigue tests simulating clinical use were carried in curved stainless steel tubes. The instruments were used in either CR or RM resulting in 4 experimental groups (n=12). The instruments were driven at 300rpm and with a standardized 4-mm pecking movement until fracture. For the RM groups, the angles were set at 140o and 45o in clockwise and counter-clockwise directions, respectively. The time of fracture and the number of cycles to fracture (NCF) for each instrument were determined. The length of the fractured file tip was measured and the fractured surface was examined with an SEM. Statistical analysis was performed on the data using two-way ANOVA and t-test.

3. Results
There were no statistically significant differences in the time to fracture or NCF between RM and CR (p>0.05) for the PF and PT groups, respectively. ProFile instruments had a significantly greater cyclic fatigue resistance compared to ProTaper regardless of the rotational movement used (p<0.05). The length of the fracture segment was not affected by either the type of the rotation (p>0.05). The fractographic analysis showed similar features for both instruments and rotational movements with the presence of crack initiation origin, crack propagation region, and overload (fast fracture) zone.
-
dc.description.tableofcontentsContents

I. Introduction....................................1
II. Materials and Methods...................3
III. Results.........................................5
IV. Discussion...................................6
V. Reference....................................9
-
dc.formatapplication/pdf-
dc.format.extent2037384 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subject.ddc617-
dc.titleThe effect of reciprocating motion on the cyclic fatigue resistance of ProFile and ProTaper-
dc.title.alternativeProFile과 ProTaper의 cyclic 피로저항에 미치는 reciprocating 운동의 효과-
dc.typeThesis-
dc.description.degreeMaster-
dc.citation.pages18-
dc.contributor.affiliation치과대학 치의학과-
dc.date.awarded2013-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share