Publications

Detailed Information

Control Method of Double Inverter Fed Wound Machine for Minimizing Copper Loss in Maximized Operating Area

DC Field Value Language
dc.contributor.authorHan, Yongsu-
dc.contributor.authorHa, Jung-Ik-
dc.creator하정익-
dc.date.accessioned2019-04-25T01:21:05Z-
dc.date.available2020-04-05T01:21:05Z-
dc.date.created2018-08-07-
dc.date.issued2017-10-
dc.identifier.citationIEEE Transactions on Industrial Electronics, Vol.64 No.10, pp.7700-7710-
dc.identifier.issn0278-0046-
dc.identifier.urihttps://hdl.handle.net/10371/149201-
dc.description.abstractA double inverter fed wound machine (DFWM) needs two inverters on the rotor as well as the stator side. This scheme gives more freedom to operation of an electric machine and improves the output power capability and the efficiency, but its control method becomes more complex because the number of control variables and the operating constraints increase. This paper deals with a control method of DFWM for minimizing the copper loss in maximized operating area. The possible operation area considering all constraints of currents, voltages, and flux is analyzed on the stator currents plane to maximize the operating area. For the minimum copper loss operation in the operating area, different modes are defined and the optimal currents are determined in each mode. Also, the optimal current selection algorithm is proposed to achieve the torque control using the optimal currents. The simulation and experimental results about wound machines are presented to show the feasibility of the proposed control method.-
dc.language영어-
dc.language.isoenen
dc.publisherInstitute of Electrical and Electronics Engineers-
dc.titleControl Method of Double Inverter Fed Wound Machine for Minimizing Copper Loss in Maximized Operating Area-
dc.typeArticle-
dc.identifier.doi10.1109/TIE.2017.2696458-
dc.citation.journaltitleIEEE Transactions on Industrial Electronics-
dc.identifier.wosid000410160200009-
dc.identifier.scopusid2-s2.0-85030088692-
dc.description.srndOAIID:RECH_ACHV_DSTSH_NO:T201738177-
dc.description.srndRECH_ACHV_FG:RR00200001-
dc.description.srndADJUST_YN:-
dc.description.srndEMP_ID:A079363-
dc.description.srndCITE_RATE:7.05-
dc.description.srndDEPT_NM:전기·정보공학부-
dc.description.srndEMAIL:jungikha@snu.ac.kr-
dc.description.srndSCOPUS_YN:Y-
dc.citation.endpage7710-
dc.citation.number10-
dc.citation.startpage7700-
dc.citation.volume64-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorHa, Jung-Ik-
dc.identifier.srndT201738177-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusINDUCTION-MOTOR DRIVE-
dc.subject.keywordPlusFREQUENCY-
dc.subject.keywordPlusTORQUE-
dc.subject.keywordAuthorDouble inverter fed wound machine (DFWM)-
dc.subject.keywordAuthorminimum copper loss (MCL)-
dc.subject.keywordAuthorvector control-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share