Publications

Detailed Information

Next-generation flexible neural and cardiac electrode arrays

DC Field Value Language
dc.contributor.authorKim, Jaemin-
dc.contributor.authorLee, Mincheol-
dc.contributor.authorRhim, Jung Soo-
dc.contributor.authorWang, Pulin-
dc.contributor.authorLu, Nanshu-
dc.contributor.authorKim, Dae-Hyeong-
dc.date.accessioned2020-02-17T04:21:59Z-
dc.date.available2020-02-17T04:21:59Z-
dc.date.created2018-07-02-
dc.date.issued2014-06-
dc.identifier.citationBiomedical Engineering Letters (BMEL), Vol.4 No.2, pp.95-108-
dc.identifier.issn2093-9868-
dc.identifier.other38445-
dc.identifier.urihttps://hdl.handle.net/10371/164288-
dc.description.abstractThe electrical activities of the brain and heart have been recorded and analyzed for diverse clinical and pathological purposes. To construct an implantable system for monitoring the electrical activity effectively, flexible and stretchable electrode arrays that are capable of making conformal contacts on the curvilinear, soft, and dynamic surfaces of the target organs have been extensively researched. Among many strategies, the most representative approach is to fabricate electrode arrays on plastic substrates to achieve more intimate and conformal contact with the target organs. Further optimizations are along with the development of ultrathin and stretchable electronics. Advanced structural modifications, such as thinning the overall profile or applying a mesh-like electrode network, have shown the greatly enhanced conformability and deformability of the device, providing improved signal-to-noise ratios (SNRs). Furthermore, brittle but high-performance silicon transistors have been successfully incorporated in flexible forms by virtue of mechanics-based active electronics designs, enabling the construction of high-density arrays comprising hundreds of multiplexed electrodes that can be individually addressed by only a few external wires. This review summarizes these strategies and describes their strengths and weaknesses, and it suggests possible technologies for nextgeneration electrode arrays. © 2014 Korean Society of Medical and Biological Engineering and Springer.-
dc.language영어-
dc.publisher대한의용생체공학회-
dc.titleNext-generation flexible neural and cardiac electrode arrays-
dc.typeArticle-
dc.identifier.doi10.1007/s13534-014-0132-4-
dc.citation.journaltitleBiomedical Engineering Letters (BMEL)-
dc.identifier.scopusid2-s2.0-84904213702-
dc.citation.endpage108-
dc.citation.number2-
dc.citation.startpage95-
dc.citation.volume4-
dc.identifier.kciidART001891402-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorKim, Dae-Hyeong-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.subject.keywordAuthorCardiac electrode array-
dc.subject.keywordAuthorFlexible electrode array-
dc.subject.keywordAuthorNeural electrode array-
dc.subject.keywordAuthorStretchable electrode array-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Engineering
  • School of Chemical and Biological Engineering
Research Area Materials Science

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share