Publications

Detailed Information

CT-monitored minimal ablative margin control in single-session microwave ablation of liver tumors: an effective strategy for local tumor control

Cited 10 time in Web of Science Cited 9 time in Scopus
Authors

Joo, Ijin; Morrow, Kenneth W.; Raman, Steven S.; McWilliams, Justin P.; Sayre, James W.; Lu, David S.

Issue Date
2022-09
Publisher
Springer Verlag
Citation
European Radiology, Vol.32 No.9, pp.6327-6335
Abstract
Objectives To investigate the usefulness of minimal ablative margin (MAM) control by intra-procedural contrast-enhanced CT (CECT) in microwave ablation (MWA) of liver tumors. Methods A total of 334 consecutive liver tumors (240 hepatocellular carcinomas [HCCs] and 94 colorectal liver metastases [CRLMs]) in 172 patients treated with percutaneous MWA were retrospectively included. MAM of each tumor was assessed after expected ablation completion using intra-procedural CECT, allowing within-session additional ablation to any potentially insufficient margin. On immediate post-MWA MRI, complete ablation coverage of tumor and final MAM status were determined. The cumulative local tumor progression (LTP) rate was estimated by using the Kaplan-Meier method. To identify predictors of LTP, Cox regression analysis with a shared frailty model was performed. Results Intra-procedural CECT findings prompted additional ablation in 18.9% (63/334) of tumors. Final complete ablation coverage of tumor and sufficient MAM were determined by MRI to be achieved in 99.4% (332/334) and 77.5% (259/334), and their estimated 6-month, 1-year, and 2-year LTP rates were 3.2%, 7.5%, and 12.9%; and 1.0%, 2.1%, and 6.9%, respectively. Insufficient MAM on post-MWA MRI, perivascular tumor location, and tumor size (cm) were independent risk factors for LTP (hazard ratio = 14.4, 6.0, and 1.1, p < 0.001, p = 0.003, and p = 0.011, respectively), while subcapsular location and histology (HCC vs CRLM) were not. Conclusions In MWA of liver tumors, intra-procedural CECT monitoring of minimal ablative margin facilitates identification of potentially suboptimal margins and guides immediate additional intra-session ablation to maximize rates of margin-sufficient ablations, the latter being a highly predictive marker for excellent long-term local tumor control.
ISSN
0938-7994
URI
https://hdl.handle.net/10371/184998
DOI
https://doi.org/10.1007/s00330-022-08723-5
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share