Publications

Detailed Information

Correlation of oocyte number with serum anti-Müllerian hormone levels measured by either Access or Elecsys in fresh in vitro fertilization cycles

Cited 1 time in Web of Science Cited 2 time in Scopus
Authors

Jeong, Hye Gyeong; Kim, Seul Ki; Lee, Jung Ryeol; Jee, Byung Chul

Issue Date
2022-08
Publisher
대한생식의학회
Citation
Clinical and Experimental Reproductive Medicine, Vol.49 No.3, pp.202-209
Abstract
© 2022 The Korean Society For Reproductive MedicineObjective: The aim of this study was to assess the correlation of oocyte number with serum anti-Müllerian hormone (AMH) levels measured by two automated methods (Access or Elecsys) in fresh stimulated in vitro fertilization (IVF) cycles. Methods: In this retrospective study at a university hospital, data were collected from 243 fresh stimulated IVF cycles performed from August 2016 to December 2020. The serum AMH level was measured by Access in 120 cycles and by Elecsys in 123 cycles. The cut-off of serum AMH for prediction of poor responders (three or fewer oocytes) or high responders (15 or more oocytes) was calculated by the receiver operating characteristic curve analysis. Results: For the two automated methods, the following equations were derived: total oocyte number=2.378+1.418×(Access-AMH) (r=0.645, p<0.001) and total oocyte number=2.417+2.163×(Elecsys-AMH) (r=0.686, p<0.001). The following combined equation could be derived: (Access-AMH)=0.028+1.525×(Elecsys-AMH). To predict poor responders, the cut-off of Access-AMH was 1.215 ng/mL (area under the curve [AUC], 0.807; 95% confidence interval [CI], 0.730–0.884; p<0.001), and the cut-off of Elecsys-AMH was 1.095 ng/mL (AUC, 0.848; 95% CI, 0.773–0.923; p<0.001). To predict high responders, the cut-off of Access-AMH was 3.450 ng/mL (AUC, 0.922; 95% CI, 0.862–0.981; p<0.001), and the cut-off of Elecsys-AMH was 2.500 ng/mL (AUC, 0.884; 95% CI, 0.778–0.991; p<0.001). Conclusion: Both automated methods for serum AMH measurement showed a good correlation with oocyte number and good performance for predicting poor and high responders in fresh stimulated IVF cycles. The Access method usually yielded higher measured serum AMH levels than the Elecsys method
ISSN
2233-8233
URI
https://hdl.handle.net/10371/186571
DOI
https://doi.org/10.5653/cerm.2022.05211
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share