Publications

Detailed Information

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

DC Field Value Language
dc.contributor.authorLee, Jungwon-
dc.contributor.authorPyo, Se-Wook-
dc.contributor.authorCho, Hyun-Jae-
dc.contributor.authorAn, Jung-Sub-
dc.contributor.authorLee, Jae-Hyun-
dc.contributor.authorKoo, Ki-Tae-
dc.contributor.authorLee, Yong-Moo-
dc.date.accessioned2023-05-03T05:45:16Z-
dc.date.available2023-05-03T05:45:16Z-
dc.date.created2020-05-12-
dc.date.created2020-05-12-
dc.date.created2020-05-12-
dc.date.created2020-05-12-
dc.date.created2020-05-12-
dc.date.issued2020-02-
dc.identifier.citationJournal of Periodontal & Implant Science, Vol.50 No.1, pp.56-66-
dc.identifier.issn2093-2278-
dc.identifier.urihttps://hdl.handle.net/10371/191784-
dc.description.abstractPurpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.-
dc.language영어-
dc.publisher대한치주과학회-
dc.titleComparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study-
dc.typeArticle-
dc.identifier.doi10.5051/jpis.2020.50.1.56-
dc.citation.journaltitleJournal of Periodontal & Implant Science-
dc.identifier.wosid000517276100007-
dc.identifier.scopusid2-s2.0-85081604560-
dc.citation.endpage66-
dc.citation.number1-
dc.citation.startpage56-
dc.citation.volume50-
dc.identifier.kciidART002559340-
dc.description.isOpenAccessY-
dc.contributor.affiliatedAuthorCho, Hyun-Jae-
dc.contributor.affiliatedAuthorLee, Jae-Hyun-
dc.contributor.affiliatedAuthorKoo, Ki-Tae-
dc.contributor.affiliatedAuthorLee, Yong-Moo-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusINSERTION TORQUE-
dc.subject.keywordPlusDENTAL IMPLANTS-
dc.subject.keywordPlusBONE LOSS-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordAuthorDental implant-
dc.subject.keywordAuthorDiagnostic techniques and procedures-
dc.subject.keywordAuthorOsseointegration-
dc.subject.keywordAuthorResonance frequency analysis-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • School of Dentistry
  • Department of Dentistry
Research Area Big Data Analysis, Dental Implant, Digital Dental Technology, 디지털 치의학, 빅데이터분석학, 임플란트학

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share