Publications

Detailed Information

Correlation between central and peripheral bone mineral density around the elbow measured by dual-energy x-ray absorptiometry in healthy children and adolescents

DC Field Value Language
dc.contributor.authorSung, Ki Hyuk-
dc.contributor.authorChung, Chin Youb-
dc.contributor.authorLee, Kyoung Min-
dc.contributor.authorLee, Jaebong-
dc.contributor.authorChung, Myung Ki-
dc.contributor.authorCho, Byung Chae-
dc.contributor.authorMoon, Seung Jun-
dc.contributor.authorPark, Moon Seok-
dc.date.accessioned2023-05-08T00:41:41Z-
dc.date.available2023-05-08T00:41:41Z-
dc.date.created2018-06-01-
dc.date.created2018-06-01-
dc.date.created2018-06-01-
dc.date.issued2017-01-
dc.identifier.citationJournal of Clinical Densitometry, Vol.20 No.1, pp.114-119-
dc.identifier.issn1094-6950-
dc.identifier.urihttps://hdl.handle.net/10371/191964-
dc.description.abstractThis pilot study was performed to evaluate the correlation between central bone mineral density (BMD) and peripheral BMD around the elbow in children and adolescents and to compare BMD values across skeletal sites. Twenty-seven healthy volunteers between 5 and 18 yr of age were recruited for the study. Anthropometric measurements including height and weight were performed. Central BMD at the lumbar spine and left femur and peripheral BMD at the supracondylar area, medial condyle, lateral condyle, and olecranon were measured using dual-energy X-ray absorptiometry (DXA). Higher BMD levels were found in the central skeleton (lumbar spine and femur) than in peripheral sites around the elbow (p < 0.001). BMD values around the elbow ranged from 44.4% to 63.2% compared to the BMD values of the central skeleton. Among the peripheral sites around the elbow, the highest BMD was observed at the supracondylar area and olecranon, and the lowest BMD was found at the lateral condyle. Peripheral DXA measurements around the elbow were significantly correlated with central DXA measurements at the lumbar spine and femur. In conclusion, this study demonstrated that the measurements of BMD around the elbow were correlated with BMD at central sites. Given the small sample size in this pilot study, further study with a large cohort is required to use the BMD measurements around the elbow as a valid clinical tool for fracture risk assessment and population based epidemiological studies.-
dc.language영어-
dc.publisherHumana Press, Inc.-
dc.titleCorrelation between central and peripheral bone mineral density around the elbow measured by dual-energy x-ray absorptiometry in healthy children and adolescents-
dc.typeArticle-
dc.identifier.doi10.1016/j.jocd.2016.04.007-
dc.citation.journaltitleJournal of Clinical Densitometry-
dc.identifier.wosid000395849400015-
dc.identifier.scopusid2-s2.0-84971351136-
dc.citation.endpage119-
dc.citation.number1-
dc.citation.startpage114-
dc.citation.volume20-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorChung, Chin Youb-
dc.contributor.affiliatedAuthorLee, Kyoung Min-
dc.contributor.affiliatedAuthorPark, Moon Seok-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusPEDIATRIC OFFICIAL POSITIONS-
dc.subject.keywordPlusOSTEOPOROTIC FRACTURE-
dc.subject.keywordPlusPHYSICAL-ACTIVITY-
dc.subject.keywordPlusREFERENCE VALUES-
dc.subject.keywordPlusKOREAN CHILDREN-
dc.subject.keywordPlusYOUNG-ADULTS-
dc.subject.keywordPlusAGE-
dc.subject.keywordPlusCHILDHOOD-
dc.subject.keywordPlusCOHORT-
dc.subject.keywordPlusMASS-
dc.subject.keywordAuthorBone mineral density-
dc.subject.keywordAuthorchildren and adolescents-
dc.subject.keywordAuthordual-energy X-ray absorptiometry-
dc.subject.keywordAuthorelbow-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Cerebral palsy, Medical image, Motion analysis, Pediatric orthopedic surgery, Statistics in orthopedic research

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share