Publications
Detailed Information
Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Seonghee | - |
dc.contributor.author | Jin, Hyeongmin | - |
dc.contributor.author | Chang, Ji Hyun | - |
dc.contributor.author | Jang, Bum‑Sup | - |
dc.contributor.author | Shin, Kyung Hwan | - |
dc.contributor.author | Choi, Chang Heon | - |
dc.contributor.author | Kim, Jung-in | - |
dc.date.accessioned | 2023-05-12T04:57:43Z | - |
dc.date.available | 2023-05-12T13:58:08Z | - |
dc.date.issued | 2023-04-04 | - |
dc.identifier.citation | Radiation Oncology, 18(1):60 | ko_KR |
dc.identifier.issn | 1748-717X | - |
dc.identifier.uri | https://hdl.handle.net/10371/192396 | - |
dc.description.abstract | Background
This study was conducted to evaluate the efficiency and accuracy of the daily patient setup for breast cancer patients by applying surface-guided radiation therapy(SGRT) using the Halcyon system instead of conventional laser alignment based on the skin marking method. Methods and materials We retrospectively investigated 228 treatment fractions using two different initial patient setup methods. The accuracy of the residual rotational error of the SGRT system was evaluated by using an in-house breast phantom. The residual translational error was analyzed using the couch position difference in the vertical, longitudinal, and lateral directions between the reference computed tomography and daily kilo-voltage cone beam computed tomography acquired from the record and verification system. The residual rotational error (pitch, yaw, and roll) was also calculated using an auto rigid registration between the two images based on Velocity. The total setup time, which combined the initial setup time and imaging time, was analyzed to evaluate the efficiency of the daily patient setup for SGRT. Results The average residual rotational errors using the in-house fabricated breast phantom for pitch, roll, and yaw were 0.14°, 0.13°, and 0.29°, respectively. The average differences in the couch positions for laser alignment based on the skin marking method were 2.7 ± 1.6mm, 2.0 ± 1.2mm, and 2.1 ± 1.0mm for the vertical, longitudinal, and lateral directions, respectively. For SGRT, the average differences in the couch positions were 1.9 ± 1.2mm, 2.9 ± 2.1mm, and 1.9 ± 0.7mm for the vertical, longitudinal, and lateral directions, respectively. The rotational errors for pitch, yaw, and roll without the surface-guided radiation therapy approach were 0.32 ± 0.30°, 0.51 ± 0.24°, and 0.29 ± 0.22°, respectively. For SGRT, the rotational errors were 0.30 ± 0.22°, 0.51 ± 0.26°, and 0.19 ± 0.13°, respectively. The average total setup times considering both the initial setup time and imaging time were 314s and 331s, respectively, with and without SGRT. Conclusion We demonstrated that using SGRT improves the accuracy and efficiency of initialpatient setups in breast cancer patients using the Halcyon system, which has limitations in correcting the rotational offset. | ko_KR |
dc.description.sponsorship | This work was supported by the National Research Foundation of Korea (NRF) grants funded by the Korea government (MSIT) (Nos. 2020R1C1C100936611 and 2020M2D9A1093990). | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | BMC | ko_KR |
dc.subject | SGRT | - |
dc.subject | Halcyon | - |
dc.subject | Residual rotational error | - |
dc.subject | Patient setup | - |
dc.title | Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system | ko_KR |
dc.type | Article | ko_KR |
dc.identifier.doi | 10.1186/s13014-023-02250-3 | ko_KR |
dc.citation.journaltitle | Radiation Oncology | ko_KR |
dc.language.rfc3066 | en | - |
dc.rights.holder | The Author(s) | - |
dc.date.updated | 2023-04-09T03:10:07Z | - |
dc.citation.number | 60 | ko_KR |
dc.citation.volume | 18 | ko_KR |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.