Publications

Detailed Information

SLIC-Occ: functional segmentation of occupancy images improves precision of EC50 images

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

Ibrahimy, Alaaddin; Hoye, Jocelyn; Wu, Hao; de Laat, Bart; Kim, Su J.; Wilson, David L.; Morris, Evan D.

Issue Date
2023-12-11
Publisher
Springer
Citation
EJNMMI Physics, Vol.10(1):80
Keywords
Drug occupancyBrain imagingPET simulationEC50 imagesFunctional clusteringAccuracy and precision
Abstract
Background
Drug occupancy studies with positron emission tomography imaging are used routinely in early phase drug development trials. Recently, our group introduced the Lassen Plot Filter, an extended version of the standard Lassen plot to estimate voxel-level occupancy images. Occupancy images can be used to create an EC50 image by applying an Emax model at each voxel. Our goal was to apply functional clustering of occupancy images via a clustering algorithm and produce a more precise EC50 image while maintaining accuracy.

Method
A digital brain phantom was used to create 10 occupancy images (corresponding to 10 different plasma concentrations of drug) that correspond to a ground truth EC50 image containing two bilateral local hot spots of high EC50 (region-1: 25; region-2: 50; background: 6–10 ng/mL). Maximum occupancy was specified as 0.85. An established noise model was applied to the simulated occupancy images and the images were smoothed. Simple Linear Iterative Clustering, an existing k-means clustering algorithm, was modified to segment a series of occupancy images into K clusters (which we call SLIC-Occ). EC50 images were estimated by nonlinear estimation at each cluster (post SLIC-Occ) and voxel (no clustering). Coefficient of variation images were estimated at each cluster and voxel, respectively. The same process was also applied to human occupancy data produced for a previously published study.

Results
Variability in EC50 estimates was reduced by more than 80% in the phantom data after application of SLIC-Occ to occupancy images with only minimal loss of accuracy. A similar, but more modest improvement was achieved in variability when SLIC-Occ was applied to human occupancy images.

Conclusions
Our results suggest that functional segmentation of occupancy images via SLIC-Occ could produce more precise EC50 images and improve our ability to identify local hot spots of high effective affinity of a drug for its target(s).
ISSN
2197-7364
Language
English
URI
https://hdl.handle.net/10371/198738
DOI
https://doi.org/10.1186/s40658-023-00600-4
Files in This Item:
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share