Average Current Mode Control in Digitally Controlled Discontinuous-Conduction-Mode PFC Rectifier for Improved Line Current Distortion
Cited 9 time in
Web of Science
Cited 10 time in Scopus
- Authors
- Issue Date
- 2011
- Publisher
- IEEE
- Citation
- 2011 TWENTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), pp.71-77
- Abstract
- This paper proposes a digital average current mode control method in discontinuous conduction mode (DCM) power factor correction (PFC) rectifier. The proposed control technique can directly sense the average value of the inductor current in each switching cycle digitally by employing a conventional current sensing circuit. Thanks to the current control loop, high speed analog-to-digital converters (ADC's) or high performance digital IC's are not needed. The technique achieves lower total harmonic distortion (THD) and higher power factor (PF) than conventional DCM PFC rectifiers. Experimental results using prototype hardware verify the feasibility and performance of the proposed sensing method.