Publications

Detailed Information

스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구 : A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants

DC Field Value Language
dc.contributor.author백상현-
dc.contributor.author허성주-
dc.contributor.author장익태-
dc.contributor.author곽재영-
dc.contributor.author김성균-
dc.date.accessioned2010-02-01T06:12:22Z-
dc.date.available2010-02-01T06:12:22Z-
dc.date.issued2008-
dc.identifier.citation2008;46:2en
dc.identifier.issn0301-2875-
dc.identifier.urihttps://hdl.handle.net/10371/47442-
dc.description.abstractStatement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: length 8.5mm 13mm splinting type Group 2: length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subjectMandibular implanten
dc.subjectFinite element analysisen
dc.subjectStress distributionen
dc.subjectSplintingen
dc.title스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구en
dc.title.alternativeA three-dimensional finite-element analysis of influence of splinting in mandibular posterior implantsen
dc.typeArticleen
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share