Publications

Detailed Information

임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향 : THE EFFECT OF PREPARATION PROCEDURE ON IMPLANT-ABUTMENT JOINT STABILITY

DC Field Value Language
dc.contributor.author이장욱-
dc.contributor.author김창회-
dc.contributor.author장경수-
dc.contributor.author임영준-
dc.date.accessioned2010-02-01T09:40:18Z-
dc.date.available2010-02-01T09:40:18Z-
dc.date.issued2005-
dc.identifier.citation2005;43(5)en
dc.identifier.issn0301-2875-
dc.identifier.urihttps://hdl.handle.net/10371/47574-
dc.description.abstractStatement of problem: Little is known about the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Purpose: This study evaluated the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Material and method: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Branemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial do-torque values were measured using digital torque gauge. After preparation of abutments, Final do-torque values were measured with digital torque gauge. Results and conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group 2. Reduction ratios of final do-torque values were greater than initial do-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final do-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subjectPreparable abutmenten
dc.subjectInitial do-torque valueen
dc.subjectFinal do-torque valueen
dc.subjectScrew looseningen
dc.subjectJoint stabilityen
dc.title임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향en
dc.title.alternativeTHE EFFECT OF PREPARATION PROCEDURE ON IMPLANT-ABUTMENT JOINT STABILITYen
dc.typeArticleen
dc.contributor.AlternativeAuthorLee, Jang-Wook-
dc.contributor.AlternativeAuthorKim, Chang-Whe-
dc.contributor.AlternativeAuthorJang, Kyung-Soo-
dc.contributor.AlternativeAuthorLim, Young-Jun-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share