smartpegTM의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향 : THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF SMARTPEGtm ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, In-Ho | - |
dc.contributor.author | Kim, Myung-Joo | - |
dc.contributor.author | Lim, Young-Jun | - |
dc.contributor.author | Kim, Chang-Whe | - |
dc.date.accessioned | 2010-02-01T09:58:04Z | - |
dc.date.available | 2010-02-01T09:58:04Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | 대한치과보철학회지 2007;45(5) | en |
dc.identifier.issn | 0301-2875 | - |
dc.identifier.uri | https://hdl.handle.net/10371/47932 | - |
dc.description.abstract | Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of on ISQ measurement. Material and methods: (Integration Diagnostics Ltd., , Sweden) of autoclave group (A) was autoclave sterilized 9 times and of reuse group (R) was reused 9 times. Ten were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. mentor (Integration Diagnostics Ltd. , Sweden) was used and type 1 (article no. 100353) was selected according to reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in was embedded in the self-curing acrylic resin (, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b ( and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of , the ISQ measurement stability did not be affected. After twice autoclave sterilization of the ISQ measurement stability was affected. | en |
dc.description.sponsorship | 이 연구는 서울대학교 신임교수 연구정착금으로 지원되는 연구비에 의하여 수행되었음. | en |
dc.language.iso | ko | en |
dc.publisher | 대한치과보철학회 | en |
dc.subject | smartpeg TM | en |
dc.subject | Autoclave Sterilization | en |
dc.subject | Reuse | en |
dc.subject | ISQ value | en |
dc.subject | Resonance Frequency Anal | en |
dc.title | smartpegTM의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향 | en |
dc.title.alternative | THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF SMARTPEGtm ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 강인호 | - |
dc.contributor.AlternativeAuthor | 김창회 | - |
dc.contributor.AlternativeAuthor | 임영준 | - |
dc.contributor.AlternativeAuthor | 김명주 | - |
- Appears in Collections:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.