Publications

Detailed Information

Microscopy coil for preoperative MRI of small soft-tissue masses of the hand and foot: comparison with conventional surface coil

DC Field Value Language
dc.contributor.authorLee, In Sook-
dc.contributor.authorChoi, Jung-Ah-
dc.contributor.authorOh, Joo Han-
dc.contributor.authorChung, Jin-Haeng-
dc.contributor.authorJeong, Hee Sun-
dc.contributor.authorHong, Sung Hwan-
dc.contributor.authorKang, Heung Sik-
dc.date.accessioned2010-04-02T05:35:35Z-
dc.date.available2010-04-02T05:35:35Z-
dc.date.issued2008-11-21-
dc.identifier.citationAJR Am J Roentgenol. 2008 ;191(6):W256-63.en
dc.identifier.issn1546-3141 (Electronic)-
dc.identifier.issn0361-803X (Print)-
dc.identifier.urihttps://hdl.handle.net/10371/62444-
dc.description.abstractOBJECTIVE: The purpose of this study was to evaluate the usefulness of MRI performed with a microscopy coil in the preoperative evaluation of small soft-tissue masses of the hand and foot. MATERIALS AND METHODS: Sixteen patients with clinically suspected soft-tissue masses of the hand or foot underwent MRI with both a conventional surface coil and a microscopy coil and were included in this study. All MR images were obtained with a 1.5-T system and a 47-mm microscopy coil. MR images were qualitatively analyzed for size, number, location, morphologic details, extent and margin quality, and growth pattern of the mass and the relation between the mass and adjacent anatomic structures. For quantitative analysis, we measured the signal-to-noise ratio of each mass on MR images obtained with both coils. MRI findings with the two coils were compared, and the findings were correlated with the surgical and histopathologic findings on all 16 patients who underwent surgery. RESULTS: Relation between adjacent anatomic structures and the mass (n = 15), internal morphologic features (n = 14), and extent or margin quality (n = 11) of masses were clearly delineated on MRI performed with a microscopy coil (p = 0.0001). These findings correlated well with the surgical and pathologic findings. In addition, small soft-tissue masses not detected with a conventional surface coil were readily detected with a microscopy coil (n = 3). The signal-to-noise ratios of masses detected with a microscopy coil were significantly higher than those of masses detected with a conventional surface coil (p = 0.006). CONCLUSION: MRI with a microscopy coil was useful in the preoperative assessment of small soft-tissue masses of the hand and foot.en
dc.language.isoenen
dc.publisherAmerican Roentgen Ray Societyen
dc.subjectAdolescenten
dc.subjectAdulten
dc.subjectAgeden
dc.subjectChilden
dc.subjectEquipment Designen
dc.subjectEquipment Failure Analysisen
dc.subjectFemaleen
dc.subjectFoot Diseases/*diagnosisen
dc.subjectHand/*pathologyen
dc.subjectHumansen
dc.subjectImage Enhancement/*instrumentationen
dc.subjectMagnetic Resonance Imaging/*instrumentation/methodsen
dc.subjectMaleen
dc.subjectMicroscopy/*instrumentationen
dc.subjectMiddle Ageden
dc.subjectPreoperative Care/methodsen
dc.subjectSensitivity and Specificityen
dc.subjectSoft Tissue Neoplasms/*diagnosisen
dc.subjectYoung Adulten
dc.subjectTransducers-
dc.titleMicroscopy coil for preoperative MRI of small soft-tissue masses of the hand and foot: comparison with conventional surface coilen
dc.typeArticleen
dc.contributor.AlternativeAuthor이인숙-
dc.contributor.AlternativeAuthor최정아-
dc.contributor.AlternativeAuthor오주한-
dc.contributor.AlternativeAuthor정진행-
dc.contributor.AlternativeAuthor정희선-
dc.contributor.AlternativeAuthor홍성환-
dc.contributor.AlternativeAuthor강흥식-
dc.identifier.doi10.2214/AJR.07.3011-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share