Publications

Detailed Information

Optimization of the contrast mixture ratio for simultaneous direct MR and CT arthrography: an in vitro study

DC Field Value Language
dc.contributor.authorChoi, Ja Young-
dc.contributor.authorKang, Heung Sik-
dc.contributor.authorHong, Sung Hwan-
dc.contributor.authorLee, Joon Woo-
dc.contributor.authorKim, Na Ra-
dc.contributor.authorJun, Woo Sun-
dc.contributor.authorMoon, Sung Gyu-
dc.contributor.authorChoi, Jung Ah-
dc.date.accessioned2010-04-08T23:32:33Z-
dc.date.available2010-04-08T23:32:33Z-
dc.date.issued2008-11-29-
dc.identifier.citationKorean J Radiol 2008;9(6):520-525en
dc.identifier.issn1229-6929 (Print)-
dc.identifier.urihttps://hdl.handle.net/10371/62742-
dc.description.abstractOBJECTIVE: This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. MATERIALS AND METHODS: An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities. RESULTS: The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging. CONCLUSION: A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography.en
dc.language.isoenen
dc.publisherKorean Radiological Societyen
dc.subjectContrast Media/*administration & dosageen
dc.subjectGadolinium/administration & dosage/*diagnostic useen
dc.subjectIohexol/administration & dosage/*analogs & derivatives/diagnostic useen
dc.subjectMeglumine/administration & dosage/*diagnostic useen
dc.subjectOrganometallic Compounds/administration & dosage/*diagnostic useen
dc.subjectPhantoms, Imagingen
dc.subjectArthrography-
dc.subjectMagnetic Resonance Imaging-
dc.subjectTomography, X-Ray Computed-
dc.titleOptimization of the contrast mixture ratio for simultaneous direct MR and CT arthrography: an in vitro studyen
dc.typeArticleen
dc.contributor.AlternativeAuthor최자영-
dc.contributor.AlternativeAuthor강흥식-
dc.contributor.AlternativeAuthor홍성환-
dc.contributor.AlternativeAuthor이준우-
dc.contributor.AlternativeAuthor김나라-
dc.contributor.AlternativeAuthor전우선-
dc.contributor.AlternativeAuthor문성규-
dc.contributor.AlternativeAuthor최정아-
dc.identifier.doi10.3348/kjr.2008.9.6.520-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share