Publications

Detailed Information

Correlation between ciliary beat frequency and metachronal wave disorder using image analysis method

DC Field Value Language
dc.contributor.authorYi, Won-Jin-
dc.contributor.authorPark, K.-S.-
dc.contributor.authorLee, C.-H.-
dc.contributor.authorRhee, C.-S.-
dc.date.accessioned2010-05-17T11:03:42Z-
dc.date.available2010-05-17T11:03:42Z-
dc.date.issued2003-07-
dc.identifier.citationMed. Biol. Eng. Comput., 41, 481-485en
dc.identifier.issn0140-0118-
dc.identifier.urihttps://hdl.handle.net/10371/66620-
dc.description.abstractCiliary beating and metachronal waves are fundamental to effective mucociliary transport. The ciliary beat frequencies (CBFs) and metachronal wave directions of multiple cilia beating in culture media were measured simultaneously using digital microscopic images. The degree of synchronisation between ciliary beats was determined by the correlation between ciliary signals at two different locations. The wave propagation directions of cilia were determined from a two-dimensional correlation map by a principal axis method. The standard deviation of measured wave directions in a region of interest was defined as a measure of metachronal wave disorder (MWD). Considerable variation was found in the beat frequencies and metachronal wave directions of cilia beating on epithelium. The pooled mean of MWDs was 23.4±8.8°, and the pooled mean of CBFs was 10.1±1.9 Hz on 120 cells from five healthy subjects. The means of the MWD and the CBF from subjects were highly correlated (correlation=−0.83). The higher the CBF, the lower the level of the MWD.en
dc.description.sponsorshipThis study was supported by a grant from the
Korea Health 21 R&D Project, Ministry of Health & Welfare,
Republic o f Korea (number 02-PJ3-PG 10-31401-0010), and this
work is also the result of research activities at the Advanced
Biometric Research Center (ABRC) supported by KOSEF.
en
dc.language.isoenen
dc.publisherSpringer Verlagen
dc.subjectImage analysis methoden
dc.subjectTwo-dimensional correlation mapen
dc.subjectPrincipal axis of inertiaen
dc.subjectCiliary beat frequencyen
dc.subjectMetachronal wave disorderen
dc.subjectCorrelation between CBF and MWDen
dc.titleCorrelation between ciliary beat frequency and metachronal wave disorder using image analysis methoden
dc.typeArticleen
dc.contributor.AlternativeAuthor이원진-
dc.identifier.doi10.1007/BF02348093-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share