Publications

Detailed Information

In vitro marginal fit of three all-ceramic corwn systems

Cited 122 time in Web of Science Cited 136 time in Scopus
Authors

Lee, Jai-Bong; Yeo, In-Sung; Yang, Jae-Ho

Issue Date
2003-11
Publisher
Elsevier
Citation
Journal of Prosthetic Dentistry 2003;90:459-464
Abstract
Statement of problem
Studies on marginal discrepancies of single restorations using various systems and materials have resulted in statistical inferences that are ambiguous because of small sample sizes and limited numbers of measurements per specimen.
Purpose
The purpose of this study was to compare the marginal adaptation of single anterior restorations made using different systems.

Material and methods
The in vitro marginal discrepancies of 3 different all-ceramic crown systems (Celay In-Ceram, conventional In-Ceram, and IPS Empress 2 layering technique), and a control group of metal ceramic restorations were evaluated and compared by measuring the gap dimension between the crowns and the prepared tooth at the marginal opening. The crowns were made for 1 extracted maxillary central incisor prepared with a 1-mm shoulder margin and 6-degree tapered walls by milling. Thirty crowns per system were fabricated. Crown measurements were recorded with an optical microscope, with an accuracy of ±0.1 μm, at 50 points spaced approximately 400 μm along the circumferential margin. The criterion of 120 μm was used as the maximum clinically acceptable marginal gap. Mean gap dimensions and standard deviations were calculated for marginal opening. The data were analyzed with a 1-way analysis of variance (α=.05).

Results
Mean gap dimensions and standard deviations at the marginal opening for the incisor crowns were 87 ± 34 μm for control, 83 ± 33 μm for Celay In-Ceram, 112 ± 55 μm for conventional In-Ceram, and 46 ± 16 μm for the IPS Empress 2 layering technique. Significant differences were found among the crown groups (P<.05). Compared with the control group, the IPS Empress 2 group had significantly smaller marginal discrepancies (P<.05), and the conventional In-Ceram group exhibited significantly greater marginal discrepancies (P<.05). There was no significant difference between the Celay In-Ceram and the control group.

Conclusion
Within the limitations of this study, the marginal discrepancies were all within the clinically acceptable standard set at 120 μm. However, the IPS Empress 2 system showed the smallest and most homogeneous gap dimension, whereas the conventional In-Ceram system presented the largest and more variable gap dimension compared with the metal ceramic (control) restoration.
ISSN
0022-3913
Language
English
URI
https://hdl.handle.net/10371/68915
DOI
https://doi.org/10.1016/j.prosdent.2003.08.005
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share