Publications

Detailed Information

Development of an Automatic Classification System for Differentiation of Obstructive Lung Disease using HRCT

DC Field Value Language
dc.contributor.authorKim, Namkug-
dc.contributor.authorSeo, Joon Beom-
dc.contributor.authorLee, Youngjoo-
dc.contributor.authorLee, June Goo-
dc.contributor.authorKang, Suk-Ho-
dc.contributor.authorKim, Song Soo-
dc.date.accessioned2012-03-05T02:29:40Z-
dc.date.available2012-03-05T02:29:40Z-
dc.date.issued2009-04-01-
dc.identifier.citationJOURNAL OF DIGITAL IMAGING; Vol.22 2; 136-148-
dc.identifier.issn0897-1889-
dc.identifier.urihttps://hdl.handle.net/10371/75323-
dc.description.abstractThe motivation is to introduce new shape features and optimize the classifier to improve performance of differentiating obstructive lung diseases, based on high-resolution computerized tomography (HRCT) images. Two hundred sixty-five HRCT images from 82 subjects were selected. On each image, two experienced radiologists selected regions of interest (ROIs) representing area of severe centrilobular emphysema, mild centrilobular emphysema, bronchiolitis obliterans, or normal lung. Besides 13 textural features, additional 11 shape features were employed to evaluate the contribution of shape features. To optimize the system, various ROI size (16 x 16, 32 x 32, and 64 x 64 pixels) and other classifier parameters were tested. For automated classification, the Bayesian classifier and support vector machine (SVM) were implemented. To assess cross-validation of the system, a five-folding method was used. In the comparison of methods employing only the textural features, adding shape features yielded the significant improvement of overall sensitivity (7.3%, 6.1%, and 4.1% in the Bayesian and 9.1%, 7.5%, and 6.4% in the SVM, in the ROI size 16 x 16, 32 x 32, 64 x 64 pixels, respectively; t test, P < 0.01). After feature selection, most of cluster shape features were survived ,and the feature selected set shows better performance of the overall sensitivity (93.5 +/- 1.0% in the SVM in the ROI size 64 x 64 pixels; t test, P < 0.01). Adding shape features to conventional texture features is much useful to improve classification performance of obstructive lung diseases in both Bayesian and SVM classifiers. In addition, the shape features contribute more to overall sensitivity in smaller ROI.-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectBayesian classifier-
dc.subjectclassifier optimization-
dc.subjectemphysema-
dc.subjectobstructive lung disease-
dc.subjectsupport vector machine-
dc.subjecttexture analysis-
dc.subjectshape analysis-
dc.subjectmachine learning-
dc.titleDevelopment of an Automatic Classification System for Differentiation of Obstructive Lung Disease using HRCT-
dc.typeArticle-
dc.contributor.AlternativeAuthor김남국-
dc.contributor.AlternativeAuthor서준범-
dc.contributor.AlternativeAuthor이영주-
dc.contributor.AlternativeAuthor이준구-
dc.contributor.AlternativeAuthor강석호-
dc.contributor.AlternativeAuthor김송수-
dc.identifier.doi10.1007/s10278-008-9147-7-
dc.citation.journaltitleJOURNAL OF DIGITAL IMAGING-
dc.description.citedreferenceXu Y, 2006, ACAD RADIOL, V13, P969, DOI 10.1016/j.acra.2006.04.017-
dc.description.citedreferenceVAPNIK VN, 2006, NATURE STAT LEARNING-
dc.description.citedreferenceHANDRICK S, 2006, P SPIE MED IM C, V6144, P1476-
dc.description.citedreferenceIwano S, 2005, COMPUT MED IMAG GRAP, V29, P565, DOI 10.1016/j.compmedimag.2005.04.009-
dc.description.citedreferenceWei LY, 2005, IEEE T MED IMAGING, V24, P371, DOI 10.1109/TMI.2004.842457-
dc.description.citedreferenceChabat F, 2003, RADIOLOGY, V228, P871, DOI 10.1148/radiol.2283020505-
dc.description.citedreferenceChan KL, 2002, IEEE T BIO-MED ENG, V49, P963, DOI 10.1109/TBME.2002.802012-
dc.description.citedreferenceCopley SJ, 2002, RADIOLOGY, V223, P812, DOI 10.1148/radiol.2233010760-
dc.description.citedreferenceGONZALEZ RC, 2002, DIGITAL IMAGE PROCES, P532-
dc.description.citedreferenceDing CHQ, 2001, BIOINFORMATICS, V17, P349-
dc.description.citedreferenceFurey TS, 2000, BIOINFORMATICS, V16, P906-
dc.description.citedreferenceZien A, 2000, BIOINFORMATICS, V16, P799-
dc.description.citedreferenceRangayyan RM, 2000, MED BIOL ENG COMPUT, V38, P487-
dc.description.citedreferenceJOACHIMS T, 1999, ADV KERNEL METHODS S-
dc.description.citedreferenceAmaldi E, 1998, THEOR COMPUT SCI, V209, P237-
dc.description.citedreferenceDumais S, 1998, IEEE INTELL SYST APP, V13, P21-
dc.description.citedreferenceBURGES CJC, 1998, DATA MIN KNOWL DISC, V2, P2-
dc.description.citedreferenceFriedman N, 1997, MACH LEARN, V29, P131-
dc.description.citedreferenceMITCHELL TM, 1997, MACHINE LEARNING-
dc.description.citedreferenceBURGES CJC, 1997, IMPROVING ACCURACY S-
dc.description.citedreferenceSCHURMANN J, 1996, PATTERN CLASSIFICATI-
dc.description.citedreferenceBOSER B, 1992, P 5 ANN WORKSH COMP, V5, P144-
dc.description.citedreferenceYAMAGISHI M, 1991, NIPPON IGAKU HOSHASE, V51, P203-
dc.description.citedreferenceKITTLER J, 1978, SIJTHOFF NOORDHOFF A, P41-
dc.description.tc5-
dc.identifier.wosid000264265000007-
Appears in Collections:
Files in This Item:
There are no files associated with this item.