Publications

Detailed Information

Real-time contrast-enhanced ultrasound-guided biopsy of focal hepatic lesions not localised on B-mode ultrasound

DC Field Value Language
dc.contributor.authorYoon, Soon Ho-
dc.contributor.authorLee, Kyoung Ho-
dc.contributor.authorKim, So Yeon-
dc.contributor.authorKim, Young Hoon-
dc.contributor.authorLee, Sang Hyub-
dc.contributor.authorKim, Tae Kyoung-
dc.contributor.authorKim, Jee Hyun-
dc.date.accessioned2012-05-25T06:31:00Z-
dc.date.available2012-05-25T06:31:00Z-
dc.date.issued2010-08-
dc.identifier.citationEUROPEAN RADIOLOGY; Vol.20 8; 2047-2056ko_KR
dc.identifier.issn0938-7994-
dc.identifier.urihttps://hdl.handle.net/10371/76477-
dc.description.abstractTo prospectively evaluate the technical feasibility of percutaneous real-time contrast-enhanced ultrasound (CEUS) guided biopsy of focal hepatic lesions that are not confidently localised on B-mode US. The study included 44 patients (mean age, 61.3 years) whose biopsy target could not be confidently localised on B-mode US performed by two independent radiologists. Biopsy was attempted under the guidance of both CEUS and B-mode US simultaneously displayed on a single monitor. Final diagnosis was established based on the pathological examination of the biopsy specimen as well as on clinical and radiological follow-up. The size and depth of the target lesions were 18.0 +/- 9.0 mm (mean +/- SD) and 41.8 +/- 17.2 mm respectively. Five patients with negative or indistinct CEUS findings did not undergo biopsy, while 39 patients completed the biopsy. In 38 of the 39 patients, the biopsy result was concordant with the final diagnosis. In the remaining one patient, the biopsy failed to prove metastasis. As there were six cases of technical failure, the technical success rate was 86% (38/44). The sensitivity in diagnosing malignancy was 88% (30/34). Real-time CEUS-guided biopsy is technically feasible for hepatic focal lesions that are not confidently localised on B-mode US.ko_KR
dc.language.isoenko_KR
dc.publisherSPRINGERko_KR
dc.subjectContrast-enhanced ultrasoundko_KR
dc.subjectHarmonic imagingko_KR
dc.subjectBiopsyko_KR
dc.titleReal-time contrast-enhanced ultrasound-guided biopsy of focal hepatic lesions not localised on B-mode ultrasoundko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor윤순호-
dc.contributor.AlternativeAuthor이경호-
dc.contributor.AlternativeAuthor김소연-
dc.contributor.AlternativeAuthor김영훈-
dc.contributor.AlternativeAuthor김지현-
dc.contributor.AlternativeAuthor이상협-
dc.contributor.AlternativeAuthor김태경-
dc.identifier.doi10.1007/s00330-010-1757-z-
dc.citation.journaltitleEUROPEAN RADIOLOGY-
dc.description.citedreferenceRhim H, 2008, AM J ROENTGENOL, V190, P1324, DOI 10.2214/AJR.07.2970-
dc.description.citedreferenceChami L, 2008, AM J ROENTGENOL, V190, P683, DOI 10.2214/AJR.07.2295-
dc.description.citedreferenceMinami Y, 2007, AM J ROENTGENOL, V188, P489, DOI 10.2214/AJR.05.1286-
dc.description.citedreferenceLencioni R, 2006, EUR RADIOL, V16, P1610, DOI 10.1007/s00330-005-0123-z-
dc.description.citedreferenceCatalano O, 2005, RADIOGRAPHICS, V25, P333, DOI 10.1148/rg.252045066-
dc.description.citedreferenceMinami Y, 2004, AM J ROENTGENOL, V183, P153-
dc.description.citedreferenceAlbrecht T, 2003, RADIOLOGY, V227, P361, DOI 10.1148/radiol.2272011833-
dc.description.citedreferenceTeefey SA, 2003, RADIOLOGY, V226, P533, DOI 10.1148/radiol.2262011980-
dc.description.citedreferenceKinkel K, 2002, RADIOLOGY, V224, P748, DOI 10.1148/radiol.2243011362-
dc.description.citedreferenceBravo AA, 2001, NEW ENGL J MED, V344, P495-
dc.description.tc3-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share