dc.description.abstractWhile computer assisted total knee arthroplasty (TKA) has been documented to increase the surgical accuracy in the planning process, there is little information about the accuracy in execution processes. We aimed to determine the accuracy of execution processes for bone resections and implant fixation in TKAs performed with the techniques of computer assisted navigation and minimally invasive surgery. Execution deviations, defined as the differences between planned targets and executed results, were evaluated for bone resections and implant fixation in 107 TKAs. In tibia resection, the mean resection thickness, coronal alignment, and sagittal alignment were 0.2 mm smaller, 0.3 degrees more valgus, 0.3 degrees less posterior slope than the planned, respectively. In femur resection, the mean resection thicknesses in the medial and lateral femoral condyles, coronal alignment, and sagittal alignment were 0.6 mm smaller, 0.8 mm smaller, 0.1 degrees more varus, and 0.7 degrees less posterior slope than the planned, respectively. In implant fixation, the mean coronal alignment and degree of extension was 0.7 degrees more valgus and 1.6 degrees decrease than the planned, respectively. Only the occurrence of unacceptable executions in implant fixation had significant effects on the final coronal alignment. The density of a bone and the quality of saw blade had significant effect on the accuracy of bone resections. Execution deviations from planned alignment commonly occur in computer-assisted minimally invasive TKA, resulting typically from the techniques of bone resections and implant fixation, and this information should be considered to improve the surgical accuracy of navigated TKAs.ko_KR
dc.language.isoenko_KR
dc.publisherELSEVIER SCIENCE BVko_KR
dc.subjectTotal knee arthroplastyko_KR
dc.subjectAccuracyko_KR
dc.subjectCement fixationko_KR
dc.subjectComputer assisted navigationko_KR
dc.subjectBone resectionsko_KR
dc.titleExecution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplastyko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor김태균-
dc.contributor.AlternativeAuthor장종범-
dc.contributor.AlternativeAuthor강연기-
dc.contributor.AlternativeAuthor정병준-
dc.contributor.AlternativeAuthor조형준-
dc.contributor.AlternativeAuthor성상철-
dc.identifier.doi10.1016/j.knee.2009.06.004-
dc.citation.journaltitleKNEE-
dc.description.citedreferenceYau WP, 2008, KNEE SURG SPORT TR A, V16, P670, DOI 10.1007/s00167-008-0550-x-
dc.description.citedreferenceBiant LC, 2008, KNEE, V15, P238, DOI 10.1016/j.knee.2008.01.012-
dc.description.citedreferenceCatani F, 2008, J BONE JOINT SURG AM, V90A, P765-
dc.description.citedreferenceYAFFE MA, 2008, CLIN ORTHOP RELAT R, V466, P236-
dc.description.citedreferencePitto RP, 2006, J BONE JOINT SURG BR, V88B, P601, DOI 10.1302/0301-620X.88B5.17431-
dc.description.citedreferenceKim WY, 2006, KNEE SURG SPORT TR A, V14, P46, DOI 10.1007/s00167-005-0627-8-
dc.description.citedreferenceOBERST M, 2006, COMPUT AIDED SURG, V11, P87-
dc.description.citedreferenceVAIL TP, 2006, SURG KNEE, V2, P1455-
dc.description.citedreferenceHAFEZ MA, 2006, SURG KNEE, V2, P1655-
dc.description.citedreferenceTRIA AJ, 2006, AM J ORTHOPSYCHIAT, V35, P18-
dc.description.citedreferenceBolognesi M, 2005, CLIN ORTHOP RELAT R, P162, DOI 10.1097/01.blo.0000186561.70566.95-
dc.description.citedreferenceJenny JY, 2005, J ARTHROPLASTY, V20, P832, DOI 10.1016/j.arth.2005.02.002-
dc.description.citedreferenceKeene GCR, 2005, J ARTHROPLASTY, V20, P798, DOI 10.1016/j.arth.2005.03.043-
dc.description.citedreferenceHaaker RG, 2005, CLIN ORTHOP RELAT R, P152, DOI 10.1097/01.blo.0000150564.31880.c4-
dc.description.citedreferenceBathis H, 2005, ARCH ORTHOP TRAUM SU, V125, P16, DOI 10.1007/s00402-004-0759-1-
dc.description.citedreferenceSTIEHL JB, 2005, TOTAL KNEE ARTHROPLA, P241-
dc.description.citedreferenceBELLEMANS J, 2005, TOTAL KNEE ARTHROPLA, P264-
dc.description.citedreferenceVictor J, 2004, CLIN ORTHOP RELAT R, P131, DOI 10.1097/01.blo.0000147710.69612.76-
dc.description.citedreferenceLaskin RS, 2004, CLIN ORTHOP RELAT R, P74, DOI 10.1097/01.blo.0000148582.86102.47-
dc.description.citedreferenceScuderi GR, 2004, CLIN ORTHOP RELAT R, P61, DOI 10.1097/01.blo.0000148574.79874.d0-
dc.description.citedreferenceHowe DJ, 2004, J BONE JOINT SURG AM, V86A, P2283-
dc.description.citedreferencePerlick L, 2004, ACTA ORTHOP SCAND, V75, P464-
dc.description.citedreferenceBathis H, 2004, J BONE JOINT SURG BR, V86B, P682, DOI 10.1302/0301-620X.86B5.14927-
dc.description.citedreferenceChauhan SK, 2004, J BONE JOINT SURG BR, V86B, P372, DOI 10.1320/0301-620X.86B3.14643-
dc.description.citedreferenceDiGioia AM, 2004, ORTHOP CLIN N AM, V35, P183, DOI 10.1016/S0030-5998(03)00133-0-
dc.description.citedreferenceBonutti PM, 2004, J BONE JOINT SURG AM, V86A, P26-
dc.description.citedreferenceNoble PC, 2003, CLIN ORTHOP RELAT R, P120, DOI 10.1097/01.blo.0000092995.90435.ee-
dc.description.citedreferenceSTULBERG DS, 2003, CLIN ORTHOP RELAT R, V416, P177-
dc.description.citedreferencePOLICE P, 2003, ADULT KNEE, P1085-
dc.description.citedreferencePlaskos C, 2002, J ARTHROPLASTY, V17, P698, DOI 10.1054/arth.2002.33564-
dc.description.citedreferenceStulberg SD, 2002, J BONE JOINT SURG AM, V84A, P90-
dc.description.citedreferenceBai B, 2000, J ARTHROPLASTY, V15, P916-
dc.description.citedreferenceOTANI T, 1993, J ARTHROPLASTY, V8, P503-
dc.description.citedreferenceLENNOX DW, 1988, ORTHOPEDICS, V11, P257-
dc.description.tc2-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share