Publications

Detailed Information

Surgical Accuracy of Maxillary Repositioning According to Type of Surgical Movement in Two-Jaw Surgery

DC Field Value Language
dc.contributor.authorChoi, Jin-Young-
dc.contributor.authorChoi, Jae-Pyong-
dc.contributor.authorBaek, Seung-Hak-
dc.date.accessioned2013-01-14T06:21:55Z-
dc.date.available2013-01-14T06:21:55Z-
dc.date.issued2009-03-
dc.identifier.citationANGLE ORTHODONTIST; Vol.79, No.2, pp.306-311ko_KR
dc.identifier.issn0003-3219-
dc.identifier.urihttps://hdl.handle.net/10371/80408-
dc.description.abstractObjective: To compare the surgical accuracy of the maxillary repositioning according to the maxillary surgical movement type (SMT) in two-jaw orthognathic surgery (TJOS). Materials and Methods: The samples consisted of 52 Korean young adult patients with skeletal Class III malocclusion treated with TJOS by one surgeon. Lateral cephalograms were taken 1 month before (TO) and 1 day after surgery (T1). The samples were allocated into maxillary advancement (MA), total setback (MS), impaction (MI), and elongation (ME) according to SMT. The distance from the upper incisor tip and the mesiobuccal cusp tip of the upper first molar to the horizontal and vertical reference lines at TO and T1 were measured. Any discrepancy between the surgical treatment objective (STO) and the surgical result less than 1 mm was regarded as accurate. The accuracy rate (AR [number of the accurate sample/number of the sample] X 1000) and the surgical achievement ratio (SAR [amount of movement in surgical result/amount of movement in STO] X 100) were calculated. Analysis variance (ANOVA) and crosstab analyses were used for statistical analysis. Results: Although the MS (69.2%) and MI (69.0%) showed a lower AR than the MA (87.5%) and ME (83.3%), there was no significant difference in the distribution of accurate and inaccurate samples among the groups. The mean discrepancy between the STO and the surgical result was less than 1 mm in all groups. Although the ME (93.54%) showed a tendency of undercorrection and the MS (107.10%) and MI (105.42%) a tendency of overcorrection, there was no significant difference in SAR among the groups. Conclusions: If the surgical plan and procedure is done with caution, the MS and MI can be regarded as just as accurate a procedure as the MA and ME. (Angle Orthod. 2009;79:306-311.)ko_KR
dc.language.isoenko_KR
dc.publisherE H ANGLE EDUCATION RESEARCH FOUNDATION, INCko_KR
dc.subjectSurgical accuracyko_KR
dc.subjectMaxillary repositioningko_KR
dc.subjectSurgical movement typeko_KR
dc.subjectTwo-jaw surgeryko_KR
dc.titleSurgical Accuracy of Maxillary Repositioning According to Type of Surgical Movement in Two-Jaw Surgeryko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor최진영-
dc.contributor.AlternativeAuthor최재평-
dc.contributor.AlternativeAuthor백승학-
dc.identifier.doi10.2319/030608-136.1-
dc.citation.journaltitleANGLE ORTHODONTIST-
dc.description.tc4-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share