Influence of instrument compliance and specimen thickness on the polymerization shrinkage stress measurement of light-cured composites

DC Field Value Language
dc.contributor.authorLee, Sue Hyun-
dc.contributor.authorChang, Juhea-
dc.contributor.authorFerracane, Jack-
dc.contributor.authorLee, In Bog-
dc.date.accessioned2013-01-14T08:01:33Z-
dc.date.available2013-01-14T08:01:33Z-
dc.date.issued2007-09-
dc.identifier.citationDENTAL MATERIALS, Vol.23, No.9, pp.1093-1100ko_KR
dc.identifier.issn0109-5641-
dc.identifier.urihttps://hdl.handle.net/10371/80497-
dc.description.abstractobjectives. The aim of our study was to investigate the effects of instrument compliance and specimen geometry on the polymerization shrinkage stress measurements of composites. Methods. A custom designed stress-strain analyzer was made using a linear variable differential transformer probe and a cantilever load cell. A sandblasted glass rod was fixed at the free end of the load cell, and another glass rod was located on a base plate. A composite was placed between the two rods and light cured. The end displacement of the load cell during polymerization was recorded for 10 min. A flowable (Filtek Flow), a universal hybrid (Z100), and a packable (P60) composite were studied. To investigate the effect of specimen geometry and instrument compliance, specimen thickness was varied between 0.5, 1.0, and 2.0 mm, and three load cells with maximum capacities of 20, 100, and 500 kgf were used. Ten maxillary premolars were prepared with two sizes of MOD cavities; the bucco-lingual widths and depths of the cavities were 1.5 mm x 2 mm and 3 mm x 2 mm, and the cusp compliance and deflection were measured before and during composite polymerization. Results. The measured polymerization stress decreased in the order of Filtek Flow, Z100, and P60 for all measurement conditions. As the specimen thickness was increased, the shrinkage stress per unit thickness (mm) decreased. The measured stress decreased with increasing instrument compliance. The cusp compliance (3.32 mu m/N) of the 3 mm x 2 mm cavities was similar to that of instrument with a 20 kgf load cell (3.34 mu m/N). Significance. For determining the most clinically relevant values for shrinkage stress of dental composites, the instrument compliance should closely match that of the tooth walls in the cavity geometry to be tested. (C) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.ko_KR
dc.language.isoenko_KR
dc.publisherELSEVIER SCI LTDko_KR
dc.subjectspecimen geometryko_KR
dc.subjectpolymerization shrinkage stressko_KR
dc.subjectcompositesko_KR
dc.subjectcomplianceko_KR
dc.titleInfluence of instrument compliance and specimen thickness on the polymerization shrinkage stress measurement of light-cured compositesko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor이수현-
dc.contributor.AlternativeAuthor장주혜-
dc.contributor.AlternativeAuthor이인복-
dc.identifier.doi10.1016/j.dental.2006.10.003-
dc.citation.journaltitleDENTAL MATERIALS-
dc.description.tc16-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share