Publications
Detailed Information
Evaluation of Early Bone Response to Fluoride-Modified and Anodically Oxidized Titanium Implants Through Continuous Removal Torque Analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwon, Taek-Ka | - |
dc.contributor.author | Lee, Hyo-Jung | - |
dc.contributor.author | Min, Seung-Ki | - |
dc.contributor.author | Yeo, In-Sung | - |
dc.creator | 여인성 | - |
dc.date.accessioned | 2013-04-16T00:26:04Z | - |
dc.date.available | 2013-04-16T00:26:04Z | - |
dc.date.issued | 2012-10 | - |
dc.identifier.citation | IMPLANT DENTISTRY Vol.21 No.5, pp. 427-432 | - |
dc.identifier.issn | 1056-6163 | - |
dc.identifier.uri | https://hdl.handle.net/10371/82038 | - |
dc.description.abstract | PURPOSE: To compare between a bioactive and a bioinert implant with different geometries by continuous measurement of the removal torque and calculation of the angular momentum of each surfaced implant.MATERIALS AND METHODS: Six New Zealand white rabbits were used in the study. Each rabbit received 2 implants. A bioactive fluoride-modified implant with a conical connection and microthread design was inserted into one tibia, and a bioinert anodically oxidized implant with an external connection design was inserted into the other. After 2 weeks of implant insertion, the removal torque values were continuously measured according to time. Using the time-torque curve resulting from the measurements, the maximum values were determined, and the angular momenta were calculated.RESULTS: The anodically oxidized implant had significantly higher peak removal torque and angular momentum values than the fluoride-modified implant (P < 0.05).CONCLUSIONS: The impact of the fluoride-modified bioactive implant on early bone response remains unclear. Considering the angular momentum of dental implants may assist in the elucidation of the effect of implant geometry on bone response. | en |
dc.language.iso | en | en |
dc.publisher | Lippincott, Williams & Wilkins | en |
dc.subject | 의약학 | en |
dc.title | Evaluation of Early Bone Response to Fluoride-Modified and Anodically Oxidized Titanium Implants Through Continuous Removal Torque Analysis | en |
dc.type | Article | - |
dc.contributor.AlternativeAuthor | 권택가 | - |
dc.contributor.AlternativeAuthor | 이효정 | - |
dc.contributor.AlternativeAuthor | 민승기 | - |
dc.contributor.AlternativeAuthor | 여인성 | - |
dc.identifier.doi | 10.1097/ID.0b013e31826917f6 | - |
dc.description.srnd | OAIID:oai:osos.snu.ac.kr:snu2012-01/102/2008003883/3 | - |
dc.description.srnd | SEQ:3 | - |
dc.description.srnd | PERF_CD:SNU2012-01 | - |
dc.description.srnd | EVAL_ITEM_CD:102 | - |
dc.description.srnd | USER_ID:2008003883 | - |
dc.description.srnd | ADJUST_YN:N | - |
dc.description.srnd | EMP_ID:A078517 | - |
dc.description.srnd | DEPT_CD:861 | - |
dc.description.srnd | CITE_RATE:1.05 | - |
dc.description.srnd | FILENAME:Implant Dent 201210 21(5) 427-32.pdf | - |
dc.description.srnd | DEPT_NM:치의학과 | - |
dc.description.srnd | EMAIL:pros53@snu.ac.kr | - |
dc.description.srnd | SCOPUS_YN:Y | - |
dc.description.srnd | CONFIRM:Y | - |
dc.identifier.srnd | 2012-01/102/2008003883/3 | - |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.