Publications
Detailed Information
Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, So-Yeun | - |
dc.contributor.author | Kim, Myung-Joo | - |
dc.contributor.author | Han, Jung-Suk | - |
dc.contributor.author | Yeo, In-Seong | - |
dc.contributor.author | Lim, Young-Jun | - |
dc.contributor.author | Kwon, Ho-Beom | - |
dc.creator | 여인성 | - |
dc.date.accessioned | 2013-07-19T02:16:37Z | - |
dc.date.available | 2013-07-19T02:16:37Z | - |
dc.date.issued | 2013-03 | - |
dc.identifier.citation | The International Journal of Prosthodontics Vol.26 No.2, pp. 161-163 | - |
dc.identifier.issn | 0893-2174 | - |
dc.identifier.uri | https://hdl.handle.net/10371/83017 | - |
dc.description.abstract | The purpose of this investigation was to measure the accuracy of digital impressions (DIs) compared to conventional impressions (CIs). Using the iTero system, a master cast was scanned to produce stereolithography dies. As a control group, silicone impressions were taken and poured using stone. The resulting stereolithography and stone dies were scanned and overlayed on the scanned reference image of the master cast. The mean (± standard deviation) dimensional difference to the master cast was 23.9 (± 17.6) ?m for DIs and 17.6 (± 45.6) μm for CIs. The results indicate that DIs also provides enough accuracy for clinical application. | en |
dc.description.abstract | The purpose of this investigation was to measure the accuracy of digital impressions
(DIs) compared to conventional impressions (CIs). Using the iTero system, a master cast was scanned to produce stereolithography dies. As a control group, silicone impressions were taken and poured using stone. The resulting stereolithography and stone dies were scanned and overlayed on the scanned reference image of the master cast. The mean (± standard deviation) dimensional difference to the master cast was 23.9 (± 17.6) µm for DIs and 17.6 (± 45.6) µm for CIs. The results indicate that DIs also provides enough accuracy for clinical application | - |
dc.description.sponsorship | This study was supported by a grant from the Seoul National University Dental Hospital Research Fund (04- 2011 -0055). The authors reported no conflicts of interest related to this study | - |
dc.language.iso | en | en |
dc.publisher | Quintessence Publishing Co Inc. | en |
dc.subject | 의약학 | en |
dc.title | Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging | en |
dc.type | Article | - |
dc.author.alternative | 김소연 | - |
dc.author.alternative | 김명주 | - |
dc.author.alternative | 한중석 | - |
dc.author.alternative | 여인성 | - |
dc.author.alternative | 임영준 | - |
dc.author.alternative | 권호범 | - |
dc.identifier.doi | 10.11607/ijp.3014 | - |
dc.citation.journaltitle | Journal of Prosthodontics | - |
dc.description.srnd | OAIID:oai:osos.snu.ac.kr:snu2013-01/102/2008003883/2 | - |
dc.description.srnd | SEQ:2 | - |
dc.description.srnd | PERF_CD:SNU2013-01 | - |
dc.description.srnd | EVAL_ITEM_CD:102 | - |
dc.description.srnd | USER_ID:2008003883 | - |
dc.description.srnd | ADJUST_YN:N | - |
dc.description.srnd | EMP_ID:A078517 | - |
dc.description.srnd | DEPT_CD:861 | - |
dc.description.srnd | CITE_RATE:1.376 | - |
dc.description.srnd | FILENAME:Int J Prosthodont 201303 26(2) 161-3.pdf | - |
dc.description.srnd | DEPT_NM:치의학과 | - |
dc.description.srnd | EMAIL:pros53@snu.ac.kr | - |
dc.description.srnd | SCOPUS_YN:Y | - |
dc.description.srnd | CONFIRM:Y | - |
dc.identifier.srnd | 2013-01/102/2008003883/2 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.