Publications
Detailed Information
Effect of thin overlapping reconstruction on the attenuation of small (< or = 3 cm) renal cysts in the nephrographic phase of MDCT: a phantom study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Sun Ho | - |
dc.contributor.author | Kim, Seung Hyup | - |
dc.date.accessioned | 2009-10-01T02:56:15Z | - |
dc.date.available | 2009-10-01T02:56:15Z | - |
dc.date.issued | 2006-12-05 | - |
dc.identifier.citation | Korean J Radiol 2006;7(4):275-80. | en |
dc.identifier.issn | 1229-6929 (Print) | - |
dc.identifier.issn | 2005-8330 (Electronic) | - |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17143031 | - |
dc.identifier.uri | https://hdl.handle.net/10371/10004 | - |
dc.description | RoMEO에 미등재 | en |
dc.description.abstract | OBJECTIVE: To evaluate the effect of thin overlapping reconstruction on the attenuation of small (< or =3 cm) renal cysts in the nephrographic phase of multidetector CT (MDCT). MATERIALS AND METHODS: We scanned a phantom kidney containing spheres of various sizes (10, 20, and 30 mm) using both 4- and 16-channel MDCT scanners, and reconstructed images with various slice thickness (T, mm) and intervals (I, mm). The attenuation increase (AI) was measured for each sphere in 240-HU diluted solution of contrast material and compared with the attenuation in 35-HU solution. RESULTS: On the 4-channel MDCT, thin overlapping reconstruction (T/I = 3/1, compared with 5/5) lowered the AI as much as 17 HU in the 10 mm-sphere and 6 HU in the 20 mm-sphere (p < 0.05). Thin slicing alone was also effective; however overlapping alone was not. On the 16-channel MDCT, AI in the 10 mm-sphere was significantly lower than on the 4-channel MDCT with T/I = 5/5 (p < 0.05), however thinner slicing or overlapping did not affect the attenuation significantly in all of the spheres. CONCLUSION: The effect of thin overlapping reconstruction on minimizing falsely elevated attenuation in the nephrographic phase was significant only in cysts < or = 20 mm on the 4-channel MDCT. | en |
dc.language.iso | en | - |
dc.publisher | The Korean Radiological Society | en |
dc.subject | Contrast Media | en |
dc.subject | Iohexol/analogs & derivatives/diagnostic use | en |
dc.subject | Kidney | en |
dc.subject | Cyst | en |
dc.subject | Computed tomography | en |
dc.subject | Pseudoenhancement | en |
dc.subject | Radiographic Image Interpretation, Computer-Assisted | - |
dc.title | Effect of thin overlapping reconstruction on the attenuation of small (< or = 3 cm) renal cysts in the nephrographic phase of MDCT: a phantom study | en |
dc.type | Article | en |