Publications

Detailed Information

Regional difference in compression artifacts in low-dose chest CT images: effects of mathematical and perceptual factors

DC Field Value Language
dc.contributor.authorKim, Kil Joong-
dc.contributor.authorKim, Bohyoung-
dc.contributor.authorLee, Kyoung Ho-
dc.contributor.authorKim, Tae Jung-
dc.contributor.authorMantiuk, Rafal-
dc.contributor.authorKang, Heung-Sik-
dc.contributor.authorKim, Young Hoon-
dc.date.accessioned2009-10-21T07:43:49Z-
dc.date.available2009-10-21T07:43:49Z-
dc.date.issued2008-
dc.identifier.citationAJR 2008; 191:W30-37en
dc.identifier.issn1546-3141 (Electronic)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18647883-
dc.identifier.urihttps://hdl.handle.net/10371/10600-
dc.description.abstractOBJECTIVE: The objective of our study was to investigate the difference of perceptible artifacts between the lungs and the chest wall and mediastinum in Joint Photographic Experts Group (JPEG) 2000-compressed low-dose chest CT images and to show that a perceptual image quality metric-the High-Dynamic Range Visual Difference Predictor (HDR-VDP)-can reproduce this regional difference. MATERIALS AND METHODS: Twenty images were compressed reversibly and irreversibly to 6:1-30:1. To analyze the two regions separately (lungs; and chest wall and mediastinum), the compressed pixels outside each tested region were replaced with the original pixels. By comparing the compressed and original images, three radiologists independently rated the compression artifacts as grade 0, none, indistinguishable; 1, barely perceptible; 2, subtle; or 3, significant. At each compression level, the two regions were compared for the readers' responses, peak signal-to-noise ratio (PSNR), and HDR-VDP results. Wilcoxon's signed rank tests and exact tests for paired proportions were used with a p value threshold of 0.05. RESULTS: Artifacts were rated as lower grades in the lungs than in the chest wall and mediastinum, showing statistical significances at 10:1-20:1 for reader 1, 8:1-15:1 for reader 2, and 8:1-20:1 for reader 3. Grade 0 was more frequent in the lungs, showing statistical significances at 10:1 for reader 1 and at 8:1-10:1 for readers 2 and 3. The results of PSNR indicated greater artifacts in the lungs (p < 0.001), whereas HDR-VDP results indicated fewer artifacts in the lungs (p < 0.001). CONCLUSION: Although compression artifacts are mathematically greater in the lungs than in the chest wall and mediastinum, radiologists' artifact perceptions are the opposite, which can be successfully reproduced by HDR-VDP.en
dc.description.sponsorshipThis work was supported by the Korea Research
Foundation Grant funded by the Korean Government
(MOEHRD) (KRF-2006-311-D00168).
en
dc.language.isoenen
dc.publisherAmerican Roentgen Ray Societyen
dc.subjectartifactsen
dc.subjectCTen
dc.subjectdata compressionen
dc.subjectimage quality metricen
dc.subjectlow-dose CTen
dc.subjectlung cancer screeningen
dc.subjectvisually lossless thresholden
dc.titleRegional difference in compression artifacts in low-dose chest CT images: effects of mathematical and perceptual factorsen
dc.typeArticleen
dc.contributor.AlternativeAuthor김길중-
dc.contributor.AlternativeAuthor김보영-
dc.contributor.AlternativeAuthor이경호-
dc.contributor.AlternativeAuthor김태정-
dc.contributor.AlternativeAuthor강형식-
dc.contributor.AlternativeAuthor김영훈-
dc.identifier.doi10.2214/AJR.07.3462-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share