Publications

Detailed Information

Mammographic density defined by higher than conventional brightness threshold better predicts breast cancer risk for full-field digital mammograms

DC Field Value Language
dc.contributor.authorNguyen, Tuong Linh-
dc.contributor.authorAung, Ye Kyaw-
dc.contributor.authorEvans, Christopher Francis-
dc.contributor.authorChoi, Yoon-Ho-
dc.contributor.authorJenkins, Mark Anthony-
dc.contributor.authorSung, Joohon-
dc.contributor.authorHopper, John Llewelyn-
dc.contributor.authorSong, Yun-Mi-
dc.date.accessioned2017-03-21T01:23:25Z-
dc.date.available2017-03-21T10:52:33Z-
dc.date.issued2015-11-18-
dc.identifier.citationBreast Cancer Research, 17(1):142ko_KR
dc.identifier.urihttps://hdl.handle.net/10371/109896-
dc.description.abstractIntroduction
When measured using the computer-assisted method CUMULUS, mammographic density adjusted for age and body mass index predicts breast cancer risk. We asked if new mammographic density measures defined by higher brightness thresholds gave better risk predictions.

Methods
The Korean Breast Cancer Study included 213 women diagnosed with invasive breast cancer and 630 controls matched for age at full-field digital mammogram and menopausal status. Mammographic density was measured using CUMULUS at the conventional threshold (Cumulus), and in effect at two increasingly higher thresholds, which we call Altocumulus and Cirrocumulus, respectively. All measures were Box-Cox transformed and adjusted for age, body mass index, menopausal status and machine. We used conditional logistic regression to estimate the change in Odds PER standard deviation of transformed and Adjusted density measures (OPERA). The area under the receiver operating characteristic curve (AUC) was estimated.

Results
Corresponding Altocumulus and Cirrocumulus density measures were correlated with Cumulus measures (r approximately 0.8 and 0.6, respectively). Altocumulus and Cirrocumulus measures were on average 25% and 80% less, respectively, than the Cumulus measure. For dense area, the OPERA was 1.18 (95% confidence interval: 1.01−1.39, P = 0.03) for Cumulus; 1.36 (1.15−1.62, P < 0.001) for Altocumulus; and 1.23 (1.04−1.45, P = 0.01) for Cirrocumulus. After fitting the Altocumulus measure, the Cumulus measure was no longer associated with risk. After fitting the Cumulus measure, the Altocumulus measure was still associated with risk (P = 0.001). The AUCs for dense area was 0.59 for the Altocumulus measure, greater than 0.55 and 0.57 for the Cumulus and Cirrocumulus measures, respectively (P = 0.001). Similar results were found for percentage dense area measures.

Conclusions
Altocumulus measures perform better than Cumulus measures in predicting breast cancer risk, and Cumulus measures are confounded by Altocumulus measures. The mammographically bright regions might be more aetiologically important for breast cancer, with implications for biological, molecular, genetic and epidemiological research and clinical translation.
ko_KR
dc.language.isoenko_KR
dc.publisherBioMed Centralko_KR
dc.titleMammographic density defined by higher than conventional brightness threshold better predicts breast cancer risk for full-field digital mammogramsko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor최윤호-
dc.contributor.AlternativeAuthor성주헌-
dc.contributor.AlternativeAuthor송윤미-
dc.identifier.doi10.1186/s13058-015-0654-4-
dc.language.rfc3066en-
dc.rights.holderNguyen et al.-
dc.date.updated2017-01-06T10:46:39Z-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share