Publications

Detailed Information

Value of high-resolution ultrasound in detecting a pneumothorax

DC Field Value Language
dc.contributor.authorChung, Myung Jin-
dc.contributor.authorGoo, Jin Mo-
dc.contributor.authorIm, Jung-Gi-
dc.contributor.authorCho, Jae Min-
dc.contributor.authorCho, Sung Bum-
dc.contributor.authorKim, Seog Joon-
dc.date.accessioned2009-11-04-
dc.date.available2009-11-04-
dc.date.issued2005-
dc.identifier.citationEur Radiol 15:930–935en
dc.identifier.issn0938-7994 (Print)-
dc.identifier.issn1432-1084 (Electronic)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=15609058-
dc.identifier.urihttps://hdl.handle.net/10371/11071-
dc.description.abstractThis study was designed to compare the detectability of high-resolution ultrasound (HRUS) and bedside chest radiography (CR) for a pneumothorax. During the last 14 months, 97 consecutive patients who were admitted to our institute to undergo a transthoracic needle aspiration and biopsy (TNAB) of the lung were included. Both HRUS and CR were performed immediately after the TNAB procedure. The HRUS images were saved in sequence using the cine-review mode and displayed as an animation on a workstation. Four radiologists independently analyzed both HRUS images and a soft copy of the CR on a diagnostic monitor and identified the pneumothorax. With CT as the reference standard, statistical parameters were calculated. From 97 patients, 35 pneumothorax cases were found on CT after the TNAB. The sensitivities in detecting the pneumothorax were 80 and 47% in HRUS and CR, respectively. The specificities were 94 and 94%. The diagnostic accuracies were 89 and 77%. The inter-observer agreement was excellent (kappa=0.85) in the HRUS images and moderate (kappa=0.49) in the CR. The results of this study suggest that HRUS is a more sensitive and confident method for diagnosing a pneumothorax when compared to bedside chest radiography.en
dc.language.isoenen
dc.publisherSpringer Verlagen
dc.subjectUltrasound, comparative studyen
dc.subjectUltrasound, utilizationen
dc.subjectThorax, USen
dc.subjectPneumothoraxen
dc.titleValue of high-resolution ultrasound in detecting a pneumothoraxen
dc.typeArticleen
dc.contributor.AlternativeAuthor정명진-
dc.contributor.AlternativeAuthor구진모-
dc.contributor.AlternativeAuthor임정기-
dc.contributor.AlternativeAuthor조재민-
dc.contributor.AlternativeAuthor조상범-
dc.contributor.AlternativeAuthor김석준-
dc.identifier.doi10.1007/s00330-004-2518-7-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share