Publications

Detailed Information

Soil-structure interaction and imperfect trench installations for deeply buried concrete pipes

DC Field Value Language
dc.contributor.authorKang, Junsuken
dc.contributor.authorParker, Frazier-
dc.contributor.authorYoo, Chai H.-
dc.creator강준석-
dc.date.accessioned2017-04-25T07:47:11Z-
dc.date.available2018-01-22T16:11:57Z-
dc.date.issued2007-03-
dc.identifier.citationJournal of Geotechnical and Geoenvironmental Engineering, Vol.133 No.3, pp. 277-285-
dc.identifier.issn1090-0241-
dc.identifier.urihttps://hdl.handle.net/10371/117541-
dc.description.abstractThe imperfect trench installation method is used to reduce earth pressure on buried concrete pipes. Few quantitative refinements to the imperfect trench installation method, however, have been added since the fundamental mechanics of the reverse arching action were proposed by Marston and Spangler. There have been limited research results published regarding, primarily, qualitative aspects of earth load reduction for imperfect trench conditions. This paper identifies variables that significantly affect earth loads, as well as the effects of bedding and sidefill treatments. An optimum geometry for imperfect trench installations with regard to a soft material zone is presented to maximize the earth load reduction effects. The optimization process was based on parametric studies of the geometry and location of the soft zone, bedding, and sidefill treatments to reduce earth pressures. Predictor equations for earth load reduction rates were formulated incorporating the optimum geometry for the soft zone and bedding and sidefill treatments.-
dc.description.sponsorshipFunding for this research project was provided by Alabama Department of Transportation under Project No. 930-592 entitled, Bedding and Fill Heights for Concrete Roadway Pipe and Box Culverts. This financial support is gratefully acknowledged.-
dc.language.isoen-
dc.publisherASCE-AMER SOC CIVIL ENGINEERSen
dc.subjectSoil-structure interaction and imperfect trench installations for deeply buried concrete pipesen
dc.subject자연과학en
dc.titleSoil-structure interaction and imperfect trench installations for deeply buried concrete pipesen
dc.typeArticle-
dc.identifier.doi10.1061/(ASCE)1090-0241(2007)133:3(277)-
dc.description.srndOAIID:RECH_ACHV_DSTSH_NO:T201702496-
dc.description.srndRECH_ACHV_FG:RR00200001-
dc.description.srndADJUST_YN:-
dc.description.srndEMP_ID:A080442-
dc.description.srndCITE_RATE:.746-
dc.description.srndDEPT_NM:조경·지역시스템공학부-
dc.description.srndSCOPUS_YN:Y-
dc.description.srndCONFIRM:Y-
dc.identifier.srndT201702496-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share