Publications

Detailed Information

Material Decomposition with the Multi-Energy Attenuation Coefficient Ratio by Using a Multiple Discriminant Analysis : 멀티에너지 감쇠계수 비의 다중판별분석법을 이용한 물질분해

DC Field Value Language
dc.contributor.advisor이원진-
dc.contributor.author이우진-
dc.date.accessioned2017-07-14T01:17:47Z-
dc.date.available2017-07-14T01:17:47Z-
dc.date.issued2016-08-
dc.identifier.other000000136894-
dc.identifier.urihttps://hdl.handle.net/10371/121811-
dc.description학위논문 (박사)-- 서울대학교 대학원 : 방사선응용생명과학전공, 2016. 8. 이원진.-
dc.description.abstractPurpose: The objective of this study was to develop a spectral CT system using a photon counting detector, and to decompose materials by applying multiple discriminant analysis (MDA) to the energy-dependent attenuation coefficient ratios.
Methods: I imaged cylindrical phantoms of PMMA with four holes filled with calcium chloride, iodine, and gold nanoparticle contrast agents. The attenuation coefficients were measured via reconstructed multi-energy images, and the linear attenuation ratio was used for material identification. The MDA projection matrix, determined from training phantoms, was used to identify the four materials in testing phantoms. For quantification purposes, relationships between attenuation coefficients at multiple energy bins and concentrations were characterized by the least square method for each material.
Results: The mean identification accuracy for each of the three materials was 0.94±0.03 for iodine, 0.96±0.02 for gold nanoparticle, and 0.92±0.05 for calcium chloride. The mean quantification errors were 1.90±1.58% for iodine, 3.85±3.13% for gold nanoparticle, and 3.40±2.62% for calcium chloride.
Conclusions: The developed multi-energy CT system based on the photon-counting detector with MDA can precisely decompose the four materials.
-
dc.description.tableofcontentsIntroduction 1

Materials and Methods 7

Results 29

Discussion 55

References 60

Abstract in Korean 72
-
dc.formatapplication/pdf-
dc.format.extent2057093 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectPhoton counting detector-
dc.subjectMulti-energy (spectral) CT-
dc.subjectMultiple discriminant analysis (MDA)-
dc.subjectMaterial decomposition-
dc.subjectConcentration quantification-
dc.subject.ddc616-
dc.titleMaterial Decomposition with the Multi-Energy Attenuation Coefficient Ratio by Using a Multiple Discriminant Analysis-
dc.title.alternative멀티에너지 감쇠계수 비의 다중판별분석법을 이용한 물질분해-
dc.typeThesis-
dc.contributor.AlternativeAuthorLee Woojin-
dc.description.degreeDoctor-
dc.citation.pages89-
dc.contributor.affiliation의과대학 협동과정 방사선응용생명과학전공-
dc.date.awarded2016-08-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share