Publications

Detailed Information

Reliability of Diffusion-Tensor Imaging Measurement Parameters in Cervical Spondylotic Myelopathy : 압박성 경추 척수증의 확산 텐서 영상: 변수 측정 방법의 신뢰도 평가

DC Field Value Language
dc.contributor.advisor이준우-
dc.contributor.author이영준-
dc.date.accessioned2017-07-14T01:18:21Z-
dc.date.available2017-07-14T01:18:21Z-
dc.date.issued2016-02-
dc.identifier.other000000132280-
dc.identifier.urihttps://hdl.handle.net/10371/121822-
dc.description학위논문 (박사)-- 서울대학교 대학원 : 의과대학 임상의과학과, 2016. 2. 이준우.-
dc.description.abstractIntroduction: The goal of this study was to assess inter and intra-observer reliability in cervical spinal cord diffusion-tensor imaging (DTI) in cases of cervical spondylotic myelopathy (CSM), as well as agreement among three different ROI measurement methods.
Methods: Institutional Review Board approval and informed consent were obtained for this study. From July of 2013 until December of 2013, 34 patients (12 male, 22 female
-
dc.description.abstractmean age 58.7 years, range 45-79 years) who underwent surgical decompression due to CSM with pre-operative DTIs were retrospectively enrolled. Four observers independently measured the fractional anisotropy (FA) values twice, using 3 different measurement methods, and a spine segment was selected for each disc level, from C1/2 to C7/T1. Inter and intra-observer reliability were assessed by interclass correlation coefficients (ICCs) and, for the test-retest reliability, the Cronbachs alpha was calculated for each observer. The differences in the mean FA values from C1/2 through C7/T1 of all of the study subjects were assessed using a paired sample T-test.
Results: The overall agreement among the 4 observers varied according to the spinal cord level and measurement methods used, ranging from poor to excellent agreement (ICC = 0.374-0.821), with relatively lower agreements in the sagittal ROI method. The radiology resident and neuro-radiologist (observers 3 and 4) showed excellent intra-observer agreement in almost every spinal cord level (ICC = 0.887-0.997). However, the inter-observer agreements varied, with fair to good agreement (ICC = 0.404-0.747). Furthermore, there was a statistically significant difference in the mean FA values from C1/2 through C7/T1 in all three measurement methods.
Conclusions: As a diagnostic tool, measured data from the DTI should have high reliability and reproducibility. In spite of the excellent intra-observer reliability of the ROI measurements, the FA values in the patients with CSM had a wide range of variation in inter-observer reliability in our study. Therefore, we should pay more attention to the interpretation of the DTI parameter for clinical usage.
-
dc.description.tableofcontentsIntroduction 1

Material and Methods 4
Study Subjects 4
DTI Protocol 5
Image and Measurement Analysis 7
Statistical Analysis 12

RESULTS 14

DISCUSSION 31

References 39

Abstract in Korean 45
-
dc.formatapplication/pdf-
dc.format.extent598906 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectCervial spondylotic Myelopathy-
dc.subjectDiffusion Tensor Imaging-
dc.subjectFractional Anisotropy-
dc.subjectMagnetic Resonance Imaging-
dc.subjectReliability-
dc.subject.ddc610-
dc.titleReliability of Diffusion-Tensor Imaging Measurement Parameters in Cervical Spondylotic Myelopathy-
dc.title.alternative압박성 경추 척수증의 확산 텐서 영상: 변수 측정 방법의 신뢰도 평가-
dc.typeThesis-
dc.contributor.AlternativeAuthorEugene Lee-
dc.description.degreeDoctor-
dc.citation.pagesvii, 46-
dc.contributor.affiliation의과대학 임상의과학과-
dc.date.awarded2016-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share