Publications

Detailed Information

Effect of Resorbable Blasting Media Surface Treatment on Removal Torque of Orthodontic Mini-implants: Mechanical and Histological Analysis : 교정용 미니 임플란트의 흡수성 분사 처리가 제거토크에 미치는 영향 및 조직학적 평가

DC Field Value Language
dc.contributor.advisorTae - Woo Kim-
dc.contributor.author오돈투야-
dc.date.accessioned2017-07-14T05:50:10Z-
dc.date.available2017-07-14T05:50:10Z-
dc.date.issued2014-02-
dc.identifier.other000000018559-
dc.identifier.urihttps://hdl.handle.net/10371/125208-
dc.description학위논문 (박사)-- 서울대학교 대학원 : 치의과학과, 2014. 2. Tae - Woo Kim.-
dc.description.abstract연구목적
본 연구는 흡수성 분사 처리가 교정용 미니 임플란트의 안정성에 미치는 영향을 평가하기 위하여 제거 토크, 조직형태학적인 비교 및 형광조직학적 분석을 실시하였다.

연구방법
총 96 개의 교정용 미니 임플란트 (길이 6.0mm, 직경 1.6mm)를 표면처리하지 않은 군 (기계가공군)과, CaP 와 NHO3 로 표면을 분사처리한 군(흡수성 분사처리군)으로 나누어 토끼 경골에 식립하였으며, 식립 후 1일, 2주, 4주에 fluorescent dye를 주입하였다. 식립 후 2주 및 4주에 Maximum removal torque (MRT) 및 Removal angular momentum (RAM)을 측정하였다. 식립 후 4 주에 Bone-to-implant contact (BIC) 과 Bone area (BA)를 평가하였다. 또한 각 군의 미니 임플란트의 표면거칠기를 Optical Proplier (Wyko NT 8000, Veeco, Tucson, AZ, USA)로 분석하였다.

결과
1. 흡수성 분사처리군의 표면거칠기는 기계가공군보다 높았다.
2. 식립 후2 주에 흡수성 분사처리군의 MRT및 RAM이 기계가공군보다 유의하게 높았다.
3. 식립 후 2주에, 기계가공군에서 보다 활발한 골흡수 및 신생골 형성 등의 골리모델링이 나타났다.
4. 식립 후 4주에, 두 군간에BIC에서 유의한 차이가 없었으나, BA는 흡수성 분사처리군에서 기계가공군보다 유의성있게 높게 나타났다.

결론
기계가공군은 식립 직후, 왕성한 골 리모델링으로 인하여 초기 안정성이 취약할 수가 있지만, 흡수성 분사처리를 할 경우 식립 직후에 광범위한골흡수 등이 없어 안정적인 골 접촉을 유지함으로 인하여 초기 안정성에 더 도움을 줄 수 있다고 보인다.
-
dc.description.tableofcontentsObjective: The purpose of this study was to evaluate the effect of resorbable blasting media (RBM) treatment on the stability of the orthodontic mini-implant (OMI), using the removal torque, the histomorphometric, the histologic, and the fluorescent evaluation for healing processes of both surfaces.

Materials and Methods: Ninety six titanium OMIs with 6.0 mm length and 1.6 mm diameter, which consisted of machined group (with the machined surface) and RBM group (treated with CaP and HNO3), were implanted to the tibia of rabbits. Average roughness (Ra), mean square roughness (Rq), and maximum height of the roughness (Rz) of OMIs were analyzed by Optical Proplier (Wyko NT 8000, Veeco, Tucson, AZ, USA). Maximum removal torque (MRT) and removal angular momentum (RAM) of 16 OMIs of both groups were measured at 2 and 4 weeks after implantation. Bone-to-implant contact (BIC) and bone area (BA) of 16 OMIs of both groups were analyzed at 4 weeks after implantation. Fluorescent dyes were injected at 1 day, 2 weeks and 4 weeks after implantation and two groups were compared with a fluorescence microscope.

Results: Ra, Rq and Rz of RBM group were higher than machined group. MRT and RAM at 2 weeks of RBM group were significantly higher than machined group. Although there was no statistically significant difference in BIC, BA of RBM group was significantly higher than machined group. Machined group showed more active bone resorption and new bone formation at 2 weeks.

Conclusions: The machined surface OMI may fail at the initial stage by the active bone remodeling. And the bone apposition on RBM surface treatment can support the initial stability of the OMI although it does not increase the stability over time
-
dc.formatapplication/pdf-
dc.format.extent876930 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectMini-implant-
dc.subjectsurface treatment-
dc.subjectRBM-
dc.subjectremoval torque-
dc.subjecthistomorphometric analysis-
dc.subject.ddc617-
dc.titleEffect of Resorbable Blasting Media Surface Treatment on Removal Torque of Orthodontic Mini-implants: Mechanical and Histological Analysis-
dc.title.alternative교정용 미니 임플란트의 흡수성 분사 처리가 제거토크에 미치는 영향 및 조직학적 평가-
dc.typeThesis-
dc.contributor.AlternativeAuthorOdontuya Gansukh-
dc.description.degreeDoctor-
dc.citation.pages37-
dc.contributor.affiliation치과대학 치의과학과-
dc.date.awarded2014-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share