dc.description.abstractPURPOSE
Our aim was to investigate the reliability and teachability of a new grading system for lumbar foraminal stenosis that was introduced by Lee et al. (i.e., the Lee system). The second aim was to evaluate the correlation between the new imaging grading system and operability.

MATERIALS AND METHODS
The study was approved by the institutional review board of our hospital. A total of 100 patients (27 men, 73 women
-
dc.description.abstractmean age: 68.7 years-
dc.description.abstractage range: 60-89 years) who underwent magnetic resonance imaging (MRI) of the lumbar spine were enrolled. Two musculoskeletal radiologists, two neurosurgeons, two orthopedic surgeons, and four radiology residents independently analyzed a total of 600 lumbar foramina (both L3-L4, L4-5 and L5-S1) and graded them using the Lee system. Interobserver and interobserver agreement was analyzed using the interclass correlation coefficient (ICC), the percentage agreement, and kappa statistics. Operability of each lumbar foramen was determined by four surgeons. The correlations between operability and stenosis grading were assessed using Spearmans correlation.

RESULTS
Interobserver agreement among ten observers showed excellent reliability, as defined by the ICC value of 0.938. The average percentage agreement was 65.8%, and the overall kappa value was 0.55. The ICC for the intraobserver agreement of two observers was 0.897 and 0.787, indicating excellent agreement. The percentage agreements and kappa value were 83% (κ = 0.81) and 74% (κ = 0.65), respectively. Lumbar foraminal stenosis grading and operability were significantly correlated (rho Spearmans: 0.550, 0.717, 0.765, and 0.667
-
dc.description.abstractp < 0.0001)

CONCLUSION
The Lee system for lumbar foraminal stenosis is a reliable classification system for surgeons, radiologists, and trainees.
-
dc.description.tableofcontentsContents
Abstract............................................................................................................ i
Contents..........................................................................................................iii
List of Tables...................................................................................................iv
List of Figures..................................................................................................v
Introduction.....................................................................................................1
Materials and Methods.....................................................................................3
Results..............................................................................................................8
Discussion......................................................................................................16
References......................................................................................................21
국문초록.........................................................................................................23
-
dc.formatapplication/pdf-
dc.format.extent644590 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subject.ddc610-
dc.titleNew grading system for lumbar foraminal stenosis: Evaluation of teachability and correlation of operability-
dc.title.alternative요추 신경공 협착증: 새로운 등급 체계의 임상적 효용성-
dc.typeThesis-
dc.description.degreeMaster-
dc.citation.pages24-
dc.contributor.affiliation의과대학 의학과-
dc.date.awarded2013-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share