Publications

Detailed Information

Magnetic Resonance Elastography for the Staging of Liver Fibrosis: Comparison of Diagnostic Performance Between Patients with Chronic Hepatitis B and Those with Other Etiologies : 간 섬유화 평가를 위한 자기공명탄성영상 만성 B형 간혐 환자군과 기타 원인 환자군 사이의 진단능 비교

DC Field Value Language
dc.contributor.advisor이정민-
dc.contributor.author장원-
dc.date.accessioned2017-07-19T10:28:33Z-
dc.date.available2017-07-19T10:28:33Z-
dc.date.issued2015-02-
dc.identifier.other000000025431-
dc.identifier.urihttps://hdl.handle.net/10371/132748-
dc.description학위논문 (석사)-- 서울대학교 대학원 : 의학과, 2015. 2. 이정민.-
dc.description.abstractIntroduction: To evaluate the diagnostic performance of magnetic resonance elastography (MRE) in staging liver fibrosis (LF) in patients with chronic hepatitis B (CHB) and other etiologies.
Methods: This retrospective study was institutional review board approved and the requirement for informed consent was waived. A total of 352 patients with chronic liver diseases (280 with CHB, 26 with chronic hepatitis C (CHC), 17 with alcoholic liver disease (ALD), and 29 patients without definite etiologies) and hepatocellular carcinomas, as well as 63 living liver donors underwent MRE before surgery at our institute. Liver stiffness values (LSVs) were measured on quantitative shear-stiffness maps of MRE, and the diagnostic performance of MRE in staging LF was evaluated using receiver operating characteristic curve (ROC) analysis and the Obuchowski measure on the basis of the histopathologic analysis of LF in the CHB group and in the group comprising other etiologies.
Results: Areas under the curve (AUCs) of LSVs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) in the CHB group were 0.973 (95% confidence interval [CI], 0.930–0.977), 0.947 (95% CI, 0.918–0.969), and 0.918 (95% CI, 0,883–0.945), respectively. Obuchowski measures were similarly high in the CHB group and in the group comprising other etiologies (0.970 vs. 0.971). However, the estimated cutoff value for F4 in the CHB group was lower than those in other etiologies: 3.56 kPa vs 4.65 kPa, p< 0.001.
-
dc.description.tableofcontentsAbstract i
Contents iii
List of tables and figures iv
List of Abbreviations v

Introduction 1
Materials and Methods 4
Results 16
Discussion 24
References 29
Abstract in Korean 35
-
dc.formatapplication/pdf-
dc.format.extent773767 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectMR elastography liver-
dc.subject.ddc610-
dc.titleMagnetic Resonance Elastography for the Staging of Liver Fibrosis: Comparison of Diagnostic Performance Between Patients with Chronic Hepatitis B and Those with Other Etiologies-
dc.title.alternative간 섬유화 평가를 위한 자기공명탄성영상 만성 B형 간혐 환자군과 기타 원인 환자군 사이의 진단능 비교-
dc.typeThesis-
dc.contributor.AlternativeAuthorWon Chang-
dc.description.degreeMaster-
dc.citation.pagesv, 36-
dc.contributor.affiliation의과대학 의학과-
dc.date.awarded2015-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share