Publications

Detailed Information

Efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 in posterolateral lumbar fusion: an open, active-controlled, randomized, multicenter trial

Cited 35 time in Web of Science Cited 36 time in Scopus
Authors

Cho, Jae Hwan; Lee, Jae Hyup; Yeom, Jin Sup; Chang, Bong-Soon; Yang, Jae Jun; Koo, Ki Hyoung; Hwang, Chang Ju; Lee, Kwang Bok; Kim, Ho-Joong; Lee, Choon-Ki; Kim, Hyoungmin; Suk, Kyung-Soo; Nam, Woo Dong; Han, Jumi

Issue Date
2017-12
Publisher
Elsevier BV
Citation
Spine Journal, Vol.17 No.12, pp.1866-1874
Abstract
BACKGROUND CONTEXT: The efficacy and safety of recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute in spinal fusion has been widely researched. However, no study of the efficacy and safety of Escherichia coli-derived rhBMP-2 (E. BMP-2) with a hydroxyapatite (HA) carrier has been proposed. PURPOSE: This study aimed to compare the efficacy and safety of fusion materials between E. BMP-2 and autogenous iliac bone graft in posterolateral fusion (PLF). STUDY DESIGN/SETTING: An open, active-controlled, randomized, multicenter trial was carried out. PATIENT SAMPLE: This study included 93 patients who underwent single-level lumbar or lumbosacral PLF. OUTCOME MEASURES: The primary outcome measure was computed tomography (CT)based fusion rate at 12 and 24 weeks. Secondary outcome measures were fusion grade by radiographs and CT at 12 and 24 weeks and changes in Oswestry Disability Index (ODI), Short Form-36 (SF-36) Health Survey, and visual analogue scale (VAS). METHODS: Patients who underwent 1-level PLF (between L1 and S1) for severe spinal stenosis or grade 1 spondylolisthesis were randomized to receive E. BMP-2 with an HA carrier (E. BMP-2 group) or autogenous iliac bone graft (AIBG group). Thin-section CT (< 2 mm), VAS, ODI, and SF36 were obtained pre-and postoperatively at 12 and 24 weeks. Outcome measures were compared between the groups. RESULTS: A total of 100 patients were enrolled in this trial. Among them, 93 patients underwent planned surgery. Preoperative demographic and clinical data showed no difference between groups. CT-based fusion rates were 100.0% (41/41) for the E. BMP-2 group and 90.2% (46/51) for the AIBG group (p=. 062) at 12 weeks and 100.0% (41/41) and 94.1% (48/51) (p=. 251) at 24 weeks, respectively. Fusion grade based on radiographs and CT showed non-inferiority of the E. BMP-2 group compared with the AIBG group. All clinical parameters improved postoperatively. However, there was no difference in changes in VAS, ODI, or SF-36 between the groups. No serious adverse event related to E. BMP-2 was found. CONCLUSIONS: The fusion rate of E. BMP-2 was comparable with that of AIBG following PLF. Good clinical efficacy and safety of E. BMP-2 in spinal fusion were also revealed. It was also suggested that HA shows suitability as a carrier for E. BMP-2. Thus, E. BMP-2 with an HA carrier can be an alternative bone graft material in spinal fusion. (C) 2017 The Authors. Published by Elsevier Inc.
ISSN
1529-9430
Language
English
URI
https://hdl.handle.net/10371/148746
DOI
https://doi.org/10.1016/j.spinee.2017.06.023
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share