Publications

Detailed Information

Torsional and Bending Properties of v Taper 2H, ProTaper NEXT, NRT, and One Shape

Cited 12 time in Web of Science Cited 12 time in Scopus
Authors

Oh, Soram; Kum, Kee-Yeon; Cho, Kwon; Lee, Soo-Hyuk; You, Seung-Hyun; Go, Jonggun; Jeon, Bong-Ki; Kim, Sang-Woo; Kim, Tae-Hwan; Jang, Ji-Hyun; Perinpanayagam, Hiran; Kim, Jin-Woo; Chang, Seok Woo

Issue Date
2019-11
Publisher
Hindawi Publishing Corporation
Citation
BioMed Research International, Vol.2019, p. 6368958
Abstract
Nickel-titanium (NiTi) rotary files have enabled efficient root canal preparations that maintain the canal center with fewer aberrations compared to hand files. However, NiTi rotary files are susceptible to fracture, which can thereby compromise root canal treatment. Therefore, NiTi files have been developed to enhance fracture resistance by modifying design and thermal treatment. The objective of this study was to compare the torsional fatigue resistance and bending resistance of NiTi files manufactured from different alloys and treatments. ProTaper NEXT X2 (PTN; M-wire), V taper 2H (V2H; controlled memory wire), NRT (heat-treated), and One Shape (OS; conventional alloy) instruments of tip size #25 were compared. Torsional fatigue was evaluated by embedding the 3 mm tip of each instrument (N = 10/brand) in resin and the repetitive application of torsional stress (300 rpm, 1.0 N·cm) by an endodontic motor with autostop when the file fractured. The number of loading cycles to fracture was recorded and analyzed by Kruskal-Wallis and Mann-Whitney U tests with Bonferroni's correction. Bending resistance of the instruments was tested using a cantilever bending test to the 3 mm point from the tip (N = 10/brand). The stress was measured when deflection of 3 mm was subjected and statistically analyzed with a one-way analysis of variance and Tukey's honest significance difference test (α = 0.05). V2H withstood the highest number of load applications during torsional fatigue testing (p<0.05), followed by NRT, PTN, and OS, where the differences between NRT and PTN (p=0.035) and between PTN and OS (p=0.143) were not statistically significant. V2H showed the lowest bending stiffness, followed by NRT, PTN, and OS (p<0.001). Thermal treatment of NiTi wire resulted in improved mechanical properties, and controlled memory wire provided improved flexibility and torsional fatigue resistance.
ISSN
2314-6133
Language
ENG
URI
https://hdl.handle.net/10371/164021
DOI
https://doi.org/10.1155/2019/6368958
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share