거니 플랩이 원심팬 성능에 미치는 영향 : Impact of Gurney flap on Radial Fan Performance

DC Field Value Language
dc.contributor.advisor송성진-
dc.contributor.author장세민, 송성진-
dc.date.accessioned2020-12-28T11:52:56Z-
dc.date.available2020-12-28T11:52:56Z-
dc.date.issued2012-
dc.identifier.other000000005073-
dc.identifier.urihttps://hdl.handle.net/10371/171398-
dc.identifier.urihttp://dcollection.snu.ac.kr:80/jsp/common/DcLoOrgPer.jsp?sItemId=000000005073ko_KR
dc.description.abstractThe objective of this study is to investigate the effect of Gurney flap on radial fan performance. Gurney flaps of 1%, 2%, 3%, 5%, 7%, and 10% of blade chord length and 30°, 45°,60°, and 90° of mounting angles were investigated experimentally in this research. The radial fan with Gurney flap produced higher work coefficient than the baseline radial fan. As the Gurney flap height increases work coefficient also increases. Gurney flap of mounting angle 30° and 45° show higher work coefficient than 60° and 90°. All Gurney flaps produced higher static-to-static efficiency than the baseline case. The radial fan of h/c = 5% with 30° shows the highest maximum static-to-static efficiency with 9% increase compared to baseline fan. Gurney flaps with constant blade tip diameter were also investigated in this study. θ = 30° and 45° with h/c = 5% are selected because this two cases show the highest maximum static-to-static efficiency. The static-to-static efficiency of θ = 30° Gurney flap is higher than θ = 45° at the maximum point.-
dc.description.tableofcontentsContents

1 Introduction..........................1
2 Experimental facility……………………………………….3
2.1 Selection of Gurney flap…………………………………………………..3
2.2 Instrumentation……………………………………….………8
3 Results…………………………………………...……………12
3.1 Characteristic curves of baseline fan…………….12
3.2 Effect of Gurney flap height and mounting angle…..14
3.3 Gurney flap with constant blade tip diameter………….20
4 Conclusions……………………………………………………………………………………………...27
Reference………………………………………………………………………………………………...28
-
dc.format.extentix, 29-
dc.language.isoeng-
dc.publisher서울대학교 대학원-
dc.subjectGurney flap-
dc.subjectRadial fan-
dc.subjectFlow coefficient-
dc.subjectWork coefficient-
dc.subjectStatic to static efficiency-
dc.title거니 플랩이 원심팬 성능에 미치는 영향-
dc.title.alternativeImpact of Gurney flap on Radial Fan Performance-
dc.typeThesis-
dc.typeDissertation-
dc.contributor.AlternativeAuthorSe-min Jang and Seung-jin Song-
dc.contributor.department공과대학 기계항공공학부-
dc.description.degreeMaster-
dc.date.awarded2012-08-
dc.contributor.major터보기계-