Publications

Detailed Information

A modular X-pinch device for versatile X-pinch experiments at Seoul National University

DC Field Value Language
dc.contributor.authorRyu, Jonghyeon-
dc.contributor.authorHam, Seunggi-
dc.contributor.authorLee, Juhyeong-
dc.contributor.authorPark, JongYoon-
dc.contributor.authorPark, Sungbin-
dc.contributor.authorChoi, YeongHwan-
dc.contributor.authorWoo, H. J.-
dc.contributor.authorLee, Kern-
dc.contributor.authorGhim, Y-C-
dc.contributor.authorHwang, Y. S.-
dc.contributor.authorChung, Kyoung-Jae-
dc.date.accessioned2022-05-16T07:11:00Z-
dc.date.available2022-05-16T07:11:00Z-
dc.date.created2021-09-14-
dc.date.created2021-09-14-
dc.date.issued2021-05-
dc.identifier.citationReview of Scientific Instruments, Vol.92 No.5, p. 053533-
dc.identifier.issn0034-6748-
dc.identifier.urihttps://hdl.handle.net/10371/179748-
dc.description.abstractThis paper describes an X-pinch device recently developed at Seoul National University (SNU). The SNU X-pinch device is designed and fabricated to accommodate various diagnostics as well as conduct versatile experiments. It is easy to change the capacitance of the pulse generator because the capacitor bank has a modular design without insulation oil or gas. This allows us to perform a variety of experiments with a wide capacitance range from 80 to 800 nF. The operating voltage of the SNU X-pinch device is controlled from 20 to 100 kV by adjusting the gas pressure inside a triggered spark-gap switch. Triggering of the spark-gap switch is synchronized with the operation of a pulsed laser to diagnose the X-pinch plasma at the proper time. A large vacuum chamber precisely machined from an aluminum mono-block is attached to the top of the pulse generator. It is designed to accommodate not only various X-pinch loads but also various diagnostic apparatus such as optical components. Initial experiments with the SNU X-pinch device have successfully generated x rays with wires of various materials and sizes. The device will be used not only to explore the dynamics of X-pinch plasmas but also as a test stand for diagnostics of high-energy-density plasmas. Published under license by AIP Publishing.-
dc.language영어-
dc.publisherAmerican Institute of Physics-
dc.titleA modular X-pinch device for versatile X-pinch experiments at Seoul National University-
dc.typeArticle-
dc.identifier.doi10.1063/5.0041306-
dc.citation.journaltitleReview of Scientific Instruments-
dc.identifier.wosid000692122500002-
dc.identifier.scopusid2-s2.0-85105504958-
dc.citation.number5-
dc.citation.startpage053533-
dc.citation.volume92-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorHwang, Y. S.-
dc.contributor.affiliatedAuthorChung, Kyoung-Jae-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusRADIATION-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share