Publications

Detailed Information

Deep learning-based reconstruction of virtual monoenergetic images of kVp-switching dual energy CT for evaluation of hypervascular liver lesions: Comparison with standard reconstruction technique

DC Field Value Language
dc.contributor.authorSeo, June Young-
dc.contributor.authorJoo, Ijin-
dc.contributor.authorYoon, Jeong Hee-
dc.contributor.authorKang, Hyo Jin-
dc.contributor.authorKim, Sewoo-
dc.contributor.authorKim, Jong Hyo-
dc.contributor.authorAhn, Chulkyun-
dc.contributor.authorLee, Jeong Min-
dc.date.accessioned2022-09-29T03:17:53Z-
dc.date.available2022-09-29T03:17:53Z-
dc.date.created2022-07-12-
dc.date.issued2022-09-
dc.identifier.citationEuropean Journal of Radiology, Vol.154, p. 110390-
dc.identifier.issn0720-048X-
dc.identifier.urihttps://hdl.handle.net/10371/184603-
dc.description.abstractObjective: To investigate clinical applicability of deep learning(DL)-based reconstruction of virtual monoenergetic images(VMIs) of arterial phase liver CT obtained by rapid kVp-switching dual-energy CT for evaluation of hypervascular liver lesions. Materials and Methods: We retrospectively included 109 patients who had available late arterial phase liver CT images of the liver obtained with a rapid switching kVp DECT scanner for suspicious intra-abdominal malignancies. Two VMIs of 70 keV and 40 keV were reconstructed using adaptive statistical iterative reconstruction (ASiR-V) for arterial phase scans. VMIs at 40 keV were additionally reconstructed with a vendor-agnostic DLbased reconstruction technique (ClariCT.AI, ClariPi, DL 40 keV). Qualitative, quantitative image quality and subjective diagnostic acceptability were compared according to reconstruction techniques. Results: In qualitative analysis, DL 40 keV images showed less image noise (4.55 vs 3.11 vs 3.95, p < 0.001), better image sharpness (4.75 vs 4.16 vs 4.3, p < 0.001), better image contrast (4.98 vs 4.72 vs 4.19, p < 0.017), better lesion conspicuity (4.61 vs 4.23 vs 3.4, p < 0.001) and diagnostic acceptability (4.59 vs 3.88 vs 4.09, p < 0.001) compared with ASiR-V 40 keV or 70 keV image sets. In quantitative analysis, DL 40 keV significantly reduced image noise relative to ASiR-V 40 keV images (49.9%, p < 0.001) and ASiR-V 70 keV images (85.2%, p = 0.012). DL 40 keV images showed significantly higher CNRlesion to the liver and SNRliver than ASiR-V 40 keV image and 70 keV images (p < 0.001). Conclusion: DL-based reconstruction of 40 keV images using vendor-agnostic software showed greater noise reduction, better lesion conspicuity, image contrast, image sharpness, and higher overall image diagnostic acceptability than ASiR for 40 keV or 70 keV images in patients with hypervascular liver lesions.-
dc.language영어-
dc.publisherElsevier BV-
dc.titleDeep learning-based reconstruction of virtual monoenergetic images of kVp-switching dual energy CT for evaluation of hypervascular liver lesions: Comparison with standard reconstruction technique-
dc.typeArticle-
dc.identifier.doi10.1016/j.ejrad.2022.110390-
dc.citation.journaltitleEuropean Journal of Radiology-
dc.identifier.wosid000818381600009-
dc.identifier.scopusid2-s2.0-85132321802-
dc.citation.startpage110390-
dc.citation.volume154-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorKim, Jong Hyo-
dc.contributor.affiliatedAuthorLee, Jeong Min-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share