Publications

Detailed Information

[Cu-64]Cu-Albumin Clearance Imaging to Evaluate Lymphatic Efflux of Cerebrospinal Space Fluid in Mouse Model

DC Field Value Language
dc.contributor.authorSarker, Azmal-
dc.contributor.authorSuh, Minseok-
dc.contributor.authorChoi, Yoori-
dc.contributor.authorPark, Ji Yong-
dc.contributor.authorKwon, Seokjun-
dc.contributor.authorKim, Hyun-
dc.contributor.authorLee, Eunji-
dc.contributor.authorSeo, Hyeyeon-
dc.contributor.authorLee, Yun-Sang-
dc.contributor.authorLee, Dong Soo-
dc.date.accessioned2022-09-29T03:19:47Z-
dc.date.available2022-09-29T03:19:47Z-
dc.date.created2022-06-07-
dc.date.issued2022-06-
dc.identifier.citationNuclear Medicine and Molecular Imaging, Vol.56 No.3, pp.137-146-
dc.identifier.issn1869-3474-
dc.identifier.urihttps://hdl.handle.net/10371/184748-
dc.description.abstractPurpose Clearance of brain waste in the cerebrospinal fluid (CSF) through the meningeal lymphatic vessels (mLV) has been evaluated mostly through the fluorescent imaging which has inherent limitations in the context of animal physiology and clinical translatability. The study aimed to establish molecular imaging for the evaluation of mLV clearance function. Methods Radionuclide imaging after intrathecal (IT) injection was acquired in C57BL/6 mice of 2-9 months. The distribution of [Tc-99m]Tc-diethylenetriamine pentaacetate (DTPA) and [Cu-64]Cu-human serum albumin (HSA) was comparatively evaluated. Evans Blue and [Cu-64]Cu-HSA were used to evaluate the distribution of tracer under various speed and volume conditions. Results [Tc-99m]Tc-DTPA is not a suitable tracer for evaluation of CSF clearance via mLV as no cervical lymph node uptake was observed while it was cleared from the body. A total volume of 3 to 9 mu L at an infusion rate of 300 to 500 nL/min was not sufficient for the tracer to reach the cranial subarachnoid space and clear throughout the mLV. As a result, whole-body positron emission tomography imaging using [Cu-64]Cu-HSA at 700 nL/min, to deliver 6 mu L of injected volume, was set for characterization of the CSF to mLV clearance. Through this protocol, the mean terminal CSF clearance half-life was measured to be 123.6 min (range 117.0-135.0) in normal mice. Conclusions We established molecular imaging to evaluate CSF drainage through mLV using [Cu-64]Cu-HSA. This imaging method is expected to be extended in animal models of dysfunctional meningeal lymphatic clearance and translational research for disease-modifying therapeutic approaches.-
dc.language영어-
dc.publisher대한핵의학회-
dc.title[Cu-64]Cu-Albumin Clearance Imaging to Evaluate Lymphatic Efflux of Cerebrospinal Space Fluid in Mouse Model-
dc.typeArticle-
dc.identifier.doi10.1007/s13139-022-00746-6-
dc.citation.journaltitleNuclear Medicine and Molecular Imaging-
dc.identifier.wosid000777424600001-
dc.identifier.scopusid2-s2.0-85127550980-
dc.citation.endpage146-
dc.citation.number3-
dc.citation.startpage137-
dc.citation.volume56-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorLee, Dong Soo-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share