Deep Radiomics-based Approach to the Diagnosis of Osteoporosis Using Hip Radiographs

DC Field Value Language
dc.contributor.authorKim, Sangwook-
dc.contributor.authorKim, Bo Ram-
dc.contributor.authorChae, Hee-Dong-
dc.contributor.authorLee, Jimin-
dc.contributor.authorYe, Sung-Joon-
dc.contributor.authorKim, Dong Hyun-
dc.contributor.authorHong, Sung Hwan-
dc.contributor.authorChoi, Ja-Young-
dc.contributor.authorYoo, Hye Jin-
dc.date.accessioned2022-09-30T05:54:00Z-
dc.date.available2022-09-30T05:54:00Z-
dc.date.created2022-08-16-
dc.date.issued2022-07-
dc.identifier.citationRadiology: Artificial Intelligence, Vol.4 No.4, p. e210212-
dc.identifier.issn2638-6100-
dc.identifier.urihttps://hdl.handle.net/10371/184968-
dc.description.abstractPurpose: To develop and validate deep radiomics models for the diagnosis of osteoporosis using hip radiographs. Materials and Methods: A deep radiomics model was developed using 4924 hip radiographs from 4308 patients (3632 women; mean age, 62 years 6 13 [SD]) obtained between September 2009 and April 2020. Ten deep features, 16 texture features, and three clinical features were used to train the model. T score measured with dual-energy x-ray absorptiometry was used as a reference standard for osteoporosis. Seven deep radiomics models that combined different types of features were developed: clinical (model C); texture (model T); deep (model D); texture and clinical (model TC); deep and clinical (model DC); deep and texture (model DT); and deep, texture, and clinical features (model DTC). A total of 444 hip radiographs obtained between January 2019 and April 2020 from another institution were used for the external test. Six radiologists performed an observer performance test. The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Results: For the external test set, model D (AUC, 0.92; 95% CI: 0.89, 0.95) demonstrated higher diagnostic performance than model T (AUC, 0.77; 95% CI: 0.70, 0.83; adjusted P<.001). Model DC (AUC, 0.95; 95% CI: 0.92, 0.97; adjusted P =.03) and model DTC (AUC, 0.95; 95% CI: 0.92, 0.97; adjusted P =.048) showed improved diagnostic performance compared with model D. When observer performance without and with the assistance of the model DTC prediction was compared, performance improved from a mean AUC of 0.77 to 0.87 (P =.002). Conclusion: Deep radiomics models using hip radiographs could be used to diagnose osteoporosis with high performance. (C) RSNA, 2022-
dc.language영어-
dc.publisherRadiological Society of North America-
dc.titleDeep Radiomics-based Approach to the Diagnosis of Osteoporosis Using Hip Radiographs-
dc.typeArticle-
dc.identifier.doi10.1148/ryai.210212-
dc.citation.journaltitleRadiology: Artificial Intelligence-
dc.identifier.wosid000827900000002-
dc.identifier.scopusid2-s2.0-85134952972-
dc.citation.number4-
dc.citation.startpagee210212-
dc.citation.volume4-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorYe, Sung-Joon-
dc.contributor.affiliatedAuthorHong, Sung Hwan-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share