Publications

Detailed Information

Improved diagnostic performance of plain radiography for cervical ossification of the posterior longitudinal ligament using deep learning

Cited 0 time in Web of Science Cited 1 time in Scopus
Authors

Chae, Hee-Dong; Hong, Sung Hwan; Yeoh, Hyun Jung; Kang, Yeo Ryang; Lee, Su Min; Kim, Minyoung; Koh, Seok Young; Lee, Yongeun; Park, Moo Sung; Choi, Ja-Young; Yoo, Hye Jin

Issue Date
2022-04
Publisher
Public Library of Science
Citation
PLoS ONE, Vol.17 No.4 April, p. e0267643
Abstract
© 2022 Chae et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Background A high false-negative rate has been reported for the diagnosis of ossification of the posterior longitudinal ligament (OPLL) using plain radiography. We investigated whether deep learning (DL) can improve the diagnostic performance of radiologists for cervical OPLL using plain radiographs. Materials and methods The training set consisted of 915 radiographs from 207 patients diagnosed with OPLL. For the test set, we used 200 lateral cervical radiographs from 100 patients with cervical OPLL and 100 patients without OPLL. An observer performance study was conducted over two reading sessions. In the first session, we compared the diagnostic performance of the DL-model and the six observers. The diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC) at the vertebra and patient level. The sensitivity and specificity of the DL model and average observers were calculated in per-patient analysis. Subgroup analysis was performed according to the morphologic classification of OPLL. In the second session, observers evaluated the radiographs by referring to the results of the DL-model. Results In the vertebra-level analysis, the DL-model showed an AUC of 0.854, which was higher than the average AUC of observers (0.826), but the difference was not significant (p = 0.292). In the patient-level analysis, the performance of the DL-model had an AUC of 0.851, and the average AUC of observers was 0.841 (p = 0.739). The patient-level sensitivity and specificity were 91% and 69% in the DL model, and 83% and 68% for the average observers, respectively. Both the DL-model and observers showed decreases in overall performance in the segmental and circumscribed types. With knowledge of the results of the DL-model, the average AUC of observers increased to 0.893 (p = 0.001) at the vertebra level and 0.911 (p < 0.001) at the patient level. In the subgroup analysis, the improvement was largest in segmental-type (AUC difference 0.087; p = 0.002). Conclusions The DL-based OPLL detection model can significantly improve the diagnostic performance of radiologists on cervical radiographs.
ISSN
1932-6203
URI
https://hdl.handle.net/10371/184988
DOI
https://doi.org/10.1371/journal.pone.0267643
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share