Performance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy

DC Field Value Language
dc.contributor.authorChoun, Hyung Jin-
dc.contributor.authorKim, Jung-in-
dc.contributor.authorChoi, Chang Heon-
dc.contributor.authorJung, Seongmoon-
dc.contributor.authorJin, Hyeongmin-
dc.contributor.authorWu, Hong-Gyun-
dc.contributor.authorChie, Eui Kyu-
dc.contributor.authorPark, Jong Min-
dc.date.accessioned2022-10-17T04:17:02Z-
dc.date.available2022-10-17T04:17:02Z-
dc.date.created2022-10-13-
dc.date.issued2022-09-
dc.identifier.citationPhysical and engineering sciences in medicine, Vol.45 No.3, pp.809-816-
dc.identifier.issn2662-4729-
dc.identifier.urihttps://hdl.handle.net/10371/186169-
dc.description.abstract© 2022, Australasian College of Physical Scientists and Engineers in Medicine.The performance of a visual guidance patient-controlled (VG-PC) respiratory gating system for magnetic-resonance (MR) image-guided radiation therapy (MR-IGRT) was evaluated through a clinical trial of patients with either lung or liver cancer. Patients can voluntarily control their respiration utilizing the VG-PC respiratory gating system. The system enables patients to view near-real-time cine planar MR images projected inside the bore of MR-IGRT systems or an external screen. Twenty patients who had received stereotactic ablative radiotherapy (SABR) for lung or liver cancer were prospectively selected for this study. Before the first treatment, comprehensive instruction on the VG-PC respiratory gating system was provided to the patients. Respiratory-gated MR-IGRT was performed for each patient with it in the first fraction and then without it in the second fraction. For both the fractions, the total treatment time, beam-off time owing to the respiratory gating, and number of beam-off events were analyzed. The average total treatment time, beam-off time, and number of beam-off events with the system were 1507.3 s, 679.5 s, and 185, respectively, and those without the system were 2023.7 s (p < 0.001), 1195.0 s (p < 0.001), and 380 times (p < 0.001), respectively. The VG-PC respiratory gating system improved treatment efficiency through a reduction in the beam-off time, the number of beam-off events, and consequently the total treatment time when performing respiratory-gated MR-IGRT for lung and liver SABR.-
dc.language영어-
dc.publisherSpringer International Publishing-
dc.titlePerformance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy-
dc.typeArticle-
dc.identifier.doi10.1007/s13246-022-01144-0-
dc.citation.journaltitlePhysical and engineering sciences in medicine-
dc.identifier.wosid000813575700001-
dc.identifier.scopusid2-s2.0-85132734508-
dc.citation.endpage816-
dc.citation.number3-
dc.citation.startpage809-
dc.citation.volume45-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorPark, Jong Min-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share