Publications

Detailed Information

Accuracy of Dental Implant Placement by a Novel In-House Model-Free and Zero-Setup Fully Guided Surgical Template Made of a Light-Cured Composite Resin (VARO Guide(R)): A Comparative In Vitro Study : Accuracy of dental implant placement by a novel in-house model-free and zero-setup fully guided surgical template made of a light-cured composite resin (VARO Guide®): A comparative in vitro study

Cited 6 time in Web of Science Cited 5 time in Scopus
Authors

Song, Young-Woo; Kim, Jong-Seung; Kim, Jang-Hyun; Park, Ji-Man; Jung, Ui-Won; Cha, Jae-Kook

Issue Date
2021-07
Publisher
MDPI Open Access Publishing
Citation
Materials, Vol.14 No.14, p. 4023
Abstract
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.Background: This in vitro study mainly aimed to compare VARO Guide® to the surgical guide fabricated by CAD/CAM (NAVI Guide®) in terms of accuracy and efficacy of the implant surgery held in the dentiform model. Methods: Twenty surgeons, 10 dentists in the beginner group and 10 dentists in the expert group, participated in the study. Each surgeon conducted fully guided surgery in dentiform models twice, once with VARO Guide® (VG surgery) and the other time with a conventional type of templates, NAVI Guide® (NG surgery). Based on the superimposition of presurgical and postsurgical STL files, the positional deviations between the virtually planned and actually placed implants and the time spent on presurgical preparation and surgical procedures were estimated and compared. Results: All dimensional deviations were similar between the two groups (p > 0.05), and there was no significant difference between the expert and beginner groups regardless of the guide system. The total procedure time (mean (median)) of the VG surgery (26.33 (28.58) min) was significantly shorter than that of the NG surgery (378.83 (379.35) min; p < 0.05). While the time spent only for the fully guided implant surgery (from the start of the surgical guide sitting onto the dentiform model to the final installation of the implant fixture) was comparable (p > 0.05), the presurgical preparation time spent on virtual implant planning and surgical guide fabrication in the VG surgery (19.63 (20.93) min) was significantly shorter compared to the NG surgery (372.93 (372.95) min; p < 0.05). Conclusions: Regardless of experience, both VG and NG surgery showed reliable positional accuracy; however, the total procedure time and the preparation time were much shorter in the VG surgery compared to the NG surgery.
ISSN
1996-1944
URI
https://hdl.handle.net/10371/190574
DOI
https://doi.org/10.3390/ma14144023
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share