Publications

Detailed Information

Optical Coherence Tomography Morphologic Grading of Macular Commotio Retinae and its Association With Anatomic and Visual Outcomes

Cited 23 time in Web of Science Cited 31 time in Scopus
Authors

Ahn, Seong Joon; Woo, Se Joon; Kim, Ko Eun; Jo, Dong Hyun; Ahn, Jeeyun; Park, Kyu Hyung

Issue Date
2013-01
Publisher
Elsevier BV
Citation
American Journal of Ophthalmology, Vol.156 No.5, pp.994-1001
Abstract
PURPOSE: To investigate the morphologic characteristics of macular commotio retinae using spectral-domain optical coherence tomography (SDOCT) and develop a grading system for traumatic photoreceptor damage. DESIGN: Retrospective, observational case series. METHODS: SETTING: Seoul National University Bundang Hospital. PATIENTS: Forty-nine patients with macular commotio retinae, examined by SDOCT within 7 days of the initial traumatic event. OBSERVATIONS: A 4-step grading system was based on the morphology revealed by SDOCT. Best-corrected visual acuity (BCVA) and structural integrity of the 3 photoreceptor layers (cone outer segment tips [COST], inner/outer segment [IS-OS] junction, external limiting membrane [ELM]) were evaluated at baseline, at 1 month, and at the final visit. Visual and anatomic outcomes at 1 month and at the final visit were compared among subgroups. MAIN OUTCOME MEASURES: The severity of photoreceptor damage as revealed by SDOCT and BCVA. RESULTS: The following 4 distinct photoreceptor morphologic features were observed: increase in IS-OS junction reflectivity with the disappearance of the thin hyporeflective optical space (n = 8, grade 1), COST defect only (n = 5, grade 2), COST and IS-OS junction defects (n = 16, grade 3), and COST, IS-OS junction, and ELM defects (n = 20, grade 4). Eyes with higher grades at baseline had significantly worse visual (final BCVA, P = .002) and anatomic outcomes (complete photoreceptor recovery, P < .001). CONCLUSIONS: The number of disrupted photoreceptor layers, as determined using SDOCT images, can be used to grade macular commotio retinae. This system may be useful in documenting the baseline severity of photoreceptor damage and in predicting visual and anatomic outcomes. (C) 2013 by Elsevier Inc. All rights reserved.
ISSN
0002-9394
URI
https://hdl.handle.net/10371/191633
DOI
https://doi.org/10.1016/j.ajo.2013.06.023
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share