Publications

Detailed Information

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

Cited 20 time in Web of Science Cited 23 time in Scopus
Authors

Myagmar, Gerelmaa; Lee, Jae-Hyun; Ahn, Jin-Soo; Yeo, In-Sung Luke; Yoon, Hyung-In; Han, Jung-Suk

Issue Date
2021-06
Publisher
대한치과보철학회
Citation
Journal of Advanced Prosthodontics, Vol.13 No.3, pp.144-151
Abstract
PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using oneway analysis of variance and Tukey's post-hoc test (alpha=.05). RESULTS. The mean +/- standard deviation values of wear volume loss (in mm(3)) against the metal abrader after 60,000 cycles were 0.10 +/- 0.01 for the 3D printed resin, 0.21 +/- 0.02 for the milled resin, and 0.44 +/- 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P <.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; mu m) values for 3D printed, milled, and conventional materials were 0.59 +/- 0.06, 1.27 +/- 0.49, and 1.64 +/- 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P =.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.
ISSN
2005-7806
URI
https://hdl.handle.net/10371/191771
DOI
https://doi.org/10.4047/jap.2021.13.3.144
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • School of Dentistry
  • Department of Dentistry
Research Area Big Data Analysis, Dental Implant, Digital Dental Technology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share