Background
Chest x-ray is commonly used for pulmonary abnormality screening. However, since the image characteristics of x-rays highly depend on the machine specifications, an artificial intelligence (AI) model developed for specific equipment usually fails when clinically applied to various machines. To overcome this problem, we propose an image manipulation pipeline.

Methods
A total of 15,010 chest x-rays from systems with different generators/detectors were retrospectively collected from five institutions from May 2020 to February 2021. We developed an AI model to classify pulmonary abnormalities using x-rays from a single system. Then, we externally tested its performance on chest x-rays from various machine specifications. We compared the area under the receiver operating characteristics curve (AUC) of AI models developed using conventional image processing pipelines (histogram equalization [HE], contrast-limited histogram equalization [CLAHE], and unsharp masking [UM] with common data augmentations) with that of the proposed manipulation pipeline (XM-pipeline).

Results
The XM-pipeline model showed the highest performance for all the datasets of different machine specifications, such as chest x-rays acquired from a computed radiography system (n = 356, AUC 0.944 for XM-pipeline versus 0.917 for HE, 0.705 for CLAHE, 0.544 for UM, p
0.001, for all) and from a mobile x-ray generator (n = 204, AUC 0.949 for XM-pipeline versus 0.933 for HE, p = 0.042, 0.932 for CLAHE (p = 0.009), 0.925 for UM (p = 0.001).

Conclusions
Applying the XM-pipeline to AI training increased the diagnostic performance of the AI model on the chest x-rays of different machine configurations.

Relevance statement
The proposed training pipeline would successfully promote a wide application of the AI model for abnormality screening when chest x-rays are acquired using various x-ray machines.

Key points
• AI models developed using x-rays of a specific machine suffer from generalization.

• We proposed a new image processing pipeline to address the generalization problem.

• AI models were tested using multicenter external x-ray datasets of various machines.

• AI with our pipeline achieved the highest diagnostic performance than conventional methods.
ISSN
2509-9280
Language
English
URI
https://hdl.handle.net/10371/196143
DOI
https://doi.org/10.1186/s41747-023-00386-1
Files in This Item:
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share