Contrast reference values in panoramic radiographic images using an arch-form phantom stand
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shin, Jae-Myung | - |
dc.contributor.author | Lee, Chena | - |
dc.contributor.author | Kim, Jo-Eun | - |
dc.contributor.author | Huh, Kyung-Hoe | - |
dc.contributor.author | Yi, Won-Jin | - |
dc.contributor.author | Heo, Min-Suk | - |
dc.contributor.author | Choi, Soon-Chul | - |
dc.contributor.author | Lee, Sam-Sun | - |
dc.date.accessioned | 2023-12-11T06:41:46Z | - |
dc.date.available | 2023-12-11T06:41:46Z | - |
dc.date.created | 2018-09-17 | - |
dc.date.issued | 2016-09 | - |
dc.identifier.citation | Imaging Science in Dentistry, Vol.46 No.3, pp.203-210 | - |
dc.identifier.issn | 2233-7822 | - |
dc.identifier.uri | https://hdl.handle.net/10371/198416 | - |
dc.description.abstract | Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images. © 2016 by Korean Academy of Oral and Maxillofacial Radiology. | - |
dc.language | 영어 | - |
dc.publisher | Korean Academy of Oral and Maxillofacial Radiology | - |
dc.title | Contrast reference values in panoramic radiographic images using an arch-form phantom stand | - |
dc.type | Article | - |
dc.identifier.doi | 10.5624/isd.2016.46.3.203 | - |
dc.citation.journaltitle | Imaging Science in Dentistry | - |
dc.identifier.wosid | 000442223300007 | - |
dc.identifier.scopusid | 2-s2.0-84990976042 | - |
dc.citation.endpage | 210 | - |
dc.citation.number | 3 | - |
dc.citation.startpage | 203 | - |
dc.citation.volume | 46 | - |
dc.identifier.kciid | ART002145879 | - |
dc.description.isOpenAccess | N | - |
dc.contributor.affiliatedAuthor | Huh, Kyung-Hoe | - |
dc.contributor.affiliatedAuthor | Yi, Won-Jin | - |
dc.contributor.affiliatedAuthor | Heo, Min-Suk | - |
dc.contributor.affiliatedAuthor | Choi, Soon-Chul | - |
dc.contributor.affiliatedAuthor | Lee, Sam-Sun | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.subject.keywordAuthor | Health care | - |
dc.subject.keywordAuthor | Imaging | - |
dc.subject.keywordAuthor | Panoramic | - |
dc.subject.keywordAuthor | Phantoms | - |
dc.subject.keywordAuthor | Quality assurance | - |
dc.subject.keywordAuthor | Radiography | - |