Publications

Detailed Information

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

DC Field Value Language
dc.contributor.authorShin, Jae-Myung-
dc.contributor.authorLee, Chena-
dc.contributor.authorKim, Jo-Eun-
dc.contributor.authorHuh, Kyung-Hoe-
dc.contributor.authorYi, Won-Jin-
dc.contributor.authorHeo, Min-Suk-
dc.contributor.authorChoi, Soon-Chul-
dc.contributor.authorLee, Sam-Sun-
dc.date.accessioned2023-12-11T06:41:46Z-
dc.date.available2023-12-11T06:41:46Z-
dc.date.created2018-09-17-
dc.date.issued2016-09-
dc.identifier.citationImaging Science in Dentistry, Vol.46 No.3, pp.203-210-
dc.identifier.issn2233-7822-
dc.identifier.urihttps://hdl.handle.net/10371/198416-
dc.description.abstractPurpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images. © 2016 by Korean Academy of Oral and Maxillofacial Radiology.-
dc.language영어-
dc.publisherKorean Academy of Oral and Maxillofacial Radiology-
dc.titleContrast reference values in panoramic radiographic images using an arch-form phantom stand-
dc.typeArticle-
dc.identifier.doi10.5624/isd.2016.46.3.203-
dc.citation.journaltitleImaging Science in Dentistry-
dc.identifier.wosid000442223300007-
dc.identifier.scopusid2-s2.0-84990976042-
dc.citation.endpage210-
dc.citation.number3-
dc.citation.startpage203-
dc.citation.volume46-
dc.identifier.kciidART002145879-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorHuh, Kyung-Hoe-
dc.contributor.affiliatedAuthorYi, Won-Jin-
dc.contributor.affiliatedAuthorHeo, Min-Suk-
dc.contributor.affiliatedAuthorChoi, Soon-Chul-
dc.contributor.affiliatedAuthorLee, Sam-Sun-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordAuthorHealth care-
dc.subject.keywordAuthorImaging-
dc.subject.keywordAuthorPanoramic-
dc.subject.keywordAuthorPhantoms-
dc.subject.keywordAuthorQuality assurance-
dc.subject.keywordAuthorRadiography-